System 10: 1 collector array –
1 swimming pool in stand-alone operation
with external heat exchanger
Description of the solar function: The solar circuit pump R1 is switched
on as soon as the switch-on temperature difference between the collec-
tor array A1 (T1) and the swimming pool C1 (T) is reached. When the
switch-off temperature difference or a safety limit is reached, the solar
circuit pump R1 switches off again. The swimming pool pump is control-
led externally.
Loading strategy of solar circuit pump R1: In the factory, the load-
ing strategy is set to temperature differential control. This cannot be
altered.
Activating the system: see chapter 7.. "Selecting a system".
Terminal layout
N
L
N
R1
N
n.c. n.c.
n.c. n.c.
L
L
n.c.
n.c.
D1
T1
F1
R1
3
R2
1
2
3
4
5
X
n.c.
C1
T2
EN
 
Display: .3.3
Display: .3.3
A1: collector array
A1: collector array
C1: swimming pool
C1: swimming pool
D1: wire bridge
D1: wire bridge
F1: external heat exchanger
F1: external heat exchanger
R1: solar circuit pump
R1: solar circuit pump
T1: collector sensor
T1: collector sensor
T: sensor swimming pool
T: sensor swimming pool