English
The Alarm Ports on the DVR sport a removable terminal block.
The terminal block is used to facilitate easy connection and
disconnection of so many wires, rather than having to unscrew
each one individually if you want to move the DVR or access
the rear panel.
Alarm In 1 - 4: Connect the output from external sensors
here. Only one of the two outputs should be connected here,
the other should be connected to a 12V terminal and/or the
Ground terminal, depending on the requirements of the
sensor (consult the documentation for the sensor).
The Alarm In number does not directly correspond with a
channel number - these can be set later (see "Alarm: Sensor"
on page 46 in Advanced Configuration for details).
The Alarm & Sensor I/O Block
The Alarm I/O Block
12V: Active DC power output. Connect any sensor device
inputs which require 12V DC here. The Alarm IN connections
share common +12V DC connections.
GND: The ground connections. The Alarm IN and Alarm OUT
connections share a common ground.
Alarm Out: The outputs for connecting an external alarm
device, such as a siren or security lights, to the DVR.
N1, C1: The outputs for Alarm Out 1. Check your alarm device's
documentation to see which ports should be connected.
9