Lighting Heater Manually; Lighting Instructions; Controls - Napoleon NPS45 Installation And Operating Instructions Manual

Pellet stove heater/pellet insert heater
Table of Contents

Advertisement

8.3

LIGhTING hEATER mANUALLY

Other than placing a handful of pellets in the burn pot for lighting manually, never feed pellets
through the glass viewing door. An "OVERFIRE" condition could occur, if more pellets enter the
firebox than what the feed tube can deliver. Pellets must only be burned within the burn pot.
Your heater can be lit manually without using the automatic igniter by following the procedure below.
8.3.1
Press the ON / OFF button.
8.3.2
Place a "handful" of pellets into the burn pot.
Cover with a small amount of approved (non-volatile) fire starter gel.
8.3.3
8.3.4
Light fire starter with a match and close the viewing door.
8.4

LIGhTING INSTRUCTIONS

After filling the hopper with pellets, switch the control to manual so that you have full control of the heater until you have
familiarized yourself with its functions.
Do not try to operate your heater with the ash pan drawer, viewing door or hopper lid open. Safety switches will disable the
pellet feed auger.
Push the ON / OFF button to initiate the start-up cycle.
8.4.1
Once the start-up cycle has ended (approximately 12 to 15 minutes) adjustments can be made to the control.
8.4.2
NOTE: If the heater shuts off, empty the pellets from the burn pot and repeat steps 1 and 2.
8.5

CONTROLS

red lIGhts
solid
- Indicates set feed rates.
- When making fan adjustment, light
will indicate fan speed temporarily
and return to heat setting.
flashing
- Indicates an operation failure.
heat adJustment
Increases or decreases the heat level.
auGer feed
Speed feeding of pellets into the burn
pot.
WARNING
!
Heater may be hot.
FRONT VIEW OF LABEL
fIGure 8.5
Windows
(x7)
H
F
E
A
A
N
T
B
5.531"
HEAT
AUGER
FEED
A
.010" CLEAR LEXAN
LABEL TO BE 2 5/8" X 5 5/8"
Green lIGht
solid
POWER
- Normal operating mode.
Cutout
AUGER
flashing
- Start-up or shut down cycle.
M
AUTO
O
D
T-STAT
amber lIGht
E
MANUAL
When on, the auger is turning.
.250"
operatInG mode
Sets the heaters operating mode.
FAN
fan adJustment
Increases or decreases the speed
of the convection fan.
ON
OFF
on / off
Used to turn the heater on or off.
W385-0425 / B
2.625"
HATCHED AREA TO BE ADHESIVE
BACKED C/W PROTECTIVE
BACK VIEW
.406"
OF LABEL
.250"
.500"
.500"
TP- lIGhTING hEATER mANUAllY_PEllET
TP - OPERATION PEllET
TP - lIGhTING INSTRUCTIONS_NPS45
PAPER BACKING
W415-0702 / 10.30.08
29
B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Npi45

Table of Contents