Minimum Mantel Clearances; Rear To Top Vent Conversion Instructions - Napoleon NPS45 Installation And Operating Instructions Manual

Pellet stove heater/pellet insert heater
Table of Contents

Advertisement

26

6.3.4 mINImUm mANTEL CLEARANCES

fIGure 6.3.4

6.3.5 REAR TO TOP vENT CONvERSION INSTRUCTIONS

note: The insert is factory shipped in a rear vent configuration. Be
careful not to damage the gasket.
If installing 4" diameter vent vertically, it will be necessary to start with a 12"
section of 3" diameter vent to clear the hopper, then increase to 4" diameter
vent.
a. To vent exit vertically, remove the two screws holding the exhaust cover.
b. Remove the two screws holding the exhaust tube.
c. Attach the exhaust tube and gasket in the vertical position.
d. Attach the exhaust cover and gasket over the horizontal exit.
W415-0702 / 10.30.08
fIGure 6.3.5
exhaust cover
exhaust tube

Hide quick links: