12
2.2

hEATING SPECIFICATIONS

Approximate maximum heating Capacity (in square feet)*
burn Rate (Pounds per hour)**
maximum burn Time on low burn**
hopper Capacity
* Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature. It is
also affected by the fuel size, quality, and moisture level.
** Small pellets will increase or decrease the stated burn rates and burn times. differences of plus or minus 20% depend-
ing on fuel quality may occur.
2.3

SPECIFICATIONS

Electrical Rating
Watts during Start-Up Sequence
Watts during Operation
NPS45 Width
NPS45 height
NPS45 depth
Weight
Exhaust Collar
Intake Collar
NPS45 hopper Capacity
NPI45 hopper Capacity
EPA
burn Rate**
bTU/h**
minimum heater Opening Size
* In order to install flashing flush to finished wall and centered within the opening the front opening of the heater or enclo-
sure must be 32 5/8" wide.
2.4

SAFETY FEATURES

HIGH LIMIT SWITCH: Your heater is equipped with a high limit switch. In the event that the temperature of the heater
approaches an unsafe operating temperature, this switch will shut down the pellet feed, which will eventually shut down the
unit. If this happens, it is important to find out why the unit overheated. Contact your local dealer.
LOW LIMIT SWITCH: This switch will automatically shut down the heater if the fire goes out or fails to light within 15 minutes.
HOPPER DOOR INTERLOCK: Your heater is equipped with a micro switch in the hopper assembly that will disable the auger
when the hopper door is opened. Closing the door enables the auger, allowing pellets to feed again.
VACUUM SWITCH: This switch will sense lack of air flow through the heater and shut down the pellet feed. This lack of flow
could be caused by a blocked vent.
POWER FAILURE: In the event of a power failure, the heater will shut down. Once power is restored, the heater will re-start,
unless the convection air temperature has gone above the high limit switch setting. If this happens, contact your local dealer.
2.5

EPA COmPLIANCE

This heater is EPA exempt from Phase II
requirements, but has been tested for emissions
using EPA test methods by Warnock Hersey.
TP - PEllET SAFETY FEATURES
TP - PEllET EPA
W415-0702 / 10.30.08
800 to 2000 Sq. Feet
1.0 to 5.0
55 hours (NPS45), 45 hours (NPI45)
55 Pounds (NPS45), 45 Pounds (NPI45)
115 volts, 3.6 Amps, 60hz
400 (approximately)
180 (approximately)
22 3/8"
30 1/2"
26 5/8"
210 Pounds
3"
2"
55 Pounds
45 Pounds
Exempt
1.0 to 5.0 (Pounds Per hour)
8500 to 42500
Front: 22 1/2* W x 20 5/8 h x 14 1/4 d
We recommend that our pellet hearth
products be installed and serviced by
professionals who are certified in the
U.S. by the National Fireplace Institute
(NFI) as NFI Pellet Specialists
or who are certified in Canada
by Wood Energy Technical
Training (WETT).