Minimum Enclosure Clearances; Minimum Clearance To Combustibles - Napoleon NPS45 Installation And Operating Instructions Manual

Pellet stove heater/pellet insert heater
Table of Contents

Advertisement

6.3.2 mINImUm ENCLOSURE CLEARANCES

the stand-offs located on the back of the insert must not be removed when installing the insert into a
40"
27"
Non-combustible
floor protection

6.3.3 mINImUm CLEARANCE TO COmBUSTIBLES

Side wall to heater
mantel to top of heater
Top facing to heater
Side facing to heater
Floor protection*
* Floor Protection: minimum 6" in front of door
and to either side.
built-in combustible enclosure.
fIGure 6.3.2
6 3/8" Minimum
6"
8"
8"
6 3/8"
6"
6"*
WARNING
!
2 1/4"
10"
10" Mantel
8"
MIN
WARNING
!
!
3" all around (Refer to vent
manufacturer's instructions)
Stand-offs
7 5/8"
2 3/4"
fIGure 6.3.3
8" MIN
6"
6"
W415-0702 / 10.30.08
25