Adjustment Of The Image Erase Lamp Position - Minolta EP1054 Service Manual

Hide thumbs Also See for EP1054:
Table of Contents

Advertisement

FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 DIS/REASSEMBLY, ADJUSTMENT
98.04.13

(11) Adjustment of the Image Erase Lamp Position

Requirement
• Image erase width: Within 1 ± 0.5 mm
Important
• This adjustment must be made after the reference positions of the Multi Bypass Table
and 1st and 2nd (23 cpm copier only) Drawers have been adjusted.
1139D048AA
1139D025AA
1139D050AA
1. With the Original Cover raised, place a sheet of A4
or 8-1/2" × 11" paper lengthwise on the Original
Glass.
2. With the Original Cover raised, make a full size
copy.
3. Check the erase width on the front edge and turn
the edge erase width adjusting screw as necessary
to obtain an erase width of less than 1 ± 0.5 mm.
NOTE
Loosening the screw will make the erase width smaller.
Tightening the screw will make the erase width greater.
D-68