FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 DIS/REASSEMBLY, ADJUSTMENT
98.04.13

(2) Removal of the Paper Take-Up Rolls

1139D088AA

(3) Cleaning of the Paper Take-Up Rolls

1139D089AA

(4) Removal of the Suction Unit

1151D029AA
1151D030AA
1. Remove one screw to remove the Paper Take-Up
Roll.
1. Remove the Paper Take-Up Unit from the copier.
2. Using a soft cloth dampened with alcohol, wipe
clean the Paper Take-Up Rolls.
1. Remove the Fusing Unit. (See p. D-40.)
2. Unplug the Suction Fan connector and remove the
wire from the clamp.
3. Remove four screws to remove the Suction Unit.
D-12