FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 DIS/REASSEMBLY, ADJUSTMENT
98.04.13
2-8.

FUSING UNIT

(1) Removal of the Fusing Unit

1151D038AA
1151D007AA
1151D008AA
1139D188AA
1139D246AA
1. Remove one screw and the Ground Wire of the
Fusing Unit.
2. Unplug the Fusing Heater Lamp connector and
remove the wires from the clamp.
3. Unplug the Fusing Thermistor connector and
remove the wires from the two clamps.
4. Remove one screw and the Fusing Unit Locking
Plate.
5. Turning it in the direction of the arrow, remove the
Fusing Unit.
NOTE
When reinstalling the Fusing Unit, install the Locking
Plate as illustrated on the left.