2.2

Hull Unit

2.2.1
Wiring of transducer cable
Wire the transducer cable (14 cores) as below to prevent undue stretching during raising or
lowering operation. Fix the cable with the cable clamp on the raise/lower drive assy.
1. Fix the transducer cable from raise/lower drive assy with cable clamp [A].
Raise/lower
drive assy.
Cable clamp [B]
2. Run the cables to cable clamp [B] on the raise/lower drive assy and position it as shown
below. Temporarily tighten clamp [B].
Cable clamp [B]
a
b
c
d
e
i
k
m
j
l
w
x
y
z
Hull unit, cable clamp
Cable
clamp [A]
a
b
c
d
e
Cable clamps and positioning of cables
Cable clamp [A]
Raise/lower
shaft
i
w
Example: Wire a of clamp [A]
x
j
to a of clamp [B].
k
l
y
m
z
2. WIRING