4. Position the water valve to the left side.
5. Pull the EMI fi lter bracket straight out.
6. Using a fl at blade screwdriver, press in the 2
tabs and open the bracket.
7. Disconnect the power cord wire harness.
8. Remove the 13 mm. hex nut and ground wire
from the fi lter.
Disconnect
Ground Wire
Compressor
The compressor is a reciprocating type. Refer to the
mini-manual for the BTU/hour rating, refrigerant
type, and correct charge for this model. A 1/4-in.
O.D. copper tube is provided for access to the low
pressure side of the refrigeration system.
PTCR Relay, Run Capacitor, and Overload
Assembly
The PTCR relay, run capacitor, and overload
assembly is held to the compressor by 2 legs at the
bottom and a lock tab at the top.
To remove the PTCR relay, run capacitor, and
overload assembly:
1.
Remove the machine compartment cover. (See
Machine Compartment Cover
2.
Disconnect the PTCR relay, run capacitor, and
overload wire harness.
Disconnect
3. Using a fl at blade screwdriver, press in the
lock tab on top of the assembly and rotate the
assembly counterclockwise.
13 mm. Hex Nut
– 52 –
.)
Lock Tab