Download Print this page

Wolf OG30 Installation Manual page 12

Outdoor gas grills
Hide thumbs Also See for OG30:

Advertisement

Outdoor Grill Installation
LP Gas Installations
PORTABLE LP CONNECTION WITH TANK
3
1) Connect the
/
" flare end of the hose to the unit
8
coupling. Do not apply pipe sealant to the flare
connection.
2) Install the LP gas cylinder, pull out the shelf and place
the cylinder on it.
3) Check to ensure that the gas valve on top of the
cylinder is closed.
4) Connect the LP gas regulator to the cylinder and hand-
tighten only. Open the cylinder valve. Check for gas
leaks as described on the following page.
5) Tighten the LP tank retention screw to secure the
cylinder to the shelf.
Always check for gas leaks after changing the LP gas
cylinder. Do not place more than one LP gas cylinder in
an enclosure at one time.
The LP pressure regulator and hose supplied with the
outdoor product must be used without alteration.
LP TANK
RETENTION SCREW
Grill cart pull-out shelf.
GRILL
COUPLING
COUPLING
NUT
VENT
TO GRILL
REGULATOR
LP GAS
CYLINDER
LP gas cylinder connection.
WHOLE HOUSE LP GAS CONNECTION
The LP gas pressure regulator is not provided. It can be
purchased from your authorized Wolf dealer. For local
dealer information, visit the find a showroom section of
our website, wolfappliance.com.
The LP regulator is set for 11"
and is for use with LP only.
LP GAS SAFETY REQUIREMENT
This gas appliance and its individual shut-off valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test pres-
sures greater than .5 psi
This gas appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off
valve during pressure testing of the gas supply piping sys-
tem at test pressures equal to or less than .5 psi
LP GAS CONNECTION
A typical LP gas installation is shown in the illustrations
below. Make sure that the gas pressure regulator(s)
supplied with the outdoor product is used and installed
with the arrow on the regulator pointing towards the unit.
Do not use a replacement regulator other than that speci-
fied by Wolf. Use only gas piping that is approved for use
with natural and LP gases.
REGULATOR
REAR GAS
CONNECTION
BOTTOM GAS
CONNECTION
SHUT-OFF
VALVE
LP gas connection.
WC (water column)
(27 mb)
.
(3.5 kPa)
ADAPTER
VENT
CLOSE
NIPPLE
TO GRILL
REGULATOR
LP gas regulator.
12
.
(3.5 kPa)
FROM GAS
SUPPLY

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Og36Og42Og54Cart30Cart36Cart42