RS-232 Connector Wiring
Figure
connectors .
REMOTE
PVS 405D
RS-232
Remote RS-232
Port
Tx Rx G
NOTE:
a ground wire between
the MLC and PVS 405D.
G
Ground (Gnd)
B
Receive (Rx)
A
Transmit (Tx)
NOTE:
If you use cable that has
a drain wire, tie the drain wire
to ground at both ends.
Figure 33.
A ‑ (Rx on the MLS port)
B ‑ (Tx on the MLS port)
MLS RS‑232 Ground
Power Ground
12 V In
ATTENTION:
Heat Shrink on
Drain Wire
Figure 34.
NOTES:
33
shows the wiring for the PVS 405D and the MLC 104 IP Plus RS‑232
You must connect
B
Transmit (Tx)
Receive (Rx)
A
A B
MLS PWR
RS-232 12V
RS-232 Connector Wiring
From MLC 104 IP Plus
terminal
The length of the exposed (stripped) copper wires is important.
The ideal length is 3/16 inch (5 mm). Longer bare wires can short together.
Shorter wires are not as secure in the connectors and could be pulled out.
Wire Bared
3/16"
Heat Shrink on
(5 mm)
Outer Jacket to
Max.
Inner Conductor
Transition
7/8
"
(22 mm)
Connector Wire Preparation
•
The MLC 104 IP Plus is powered from the PVS 405D associated power supply.
•
Do not tin the power supply wires before installing them in the direct insertion
connector. Tinned wires are not as secure and could be pulled out.
G
Ground
+12 VDC input
MLC 104 IP Plus
right side panel
MLS and
Power
ports
Ground all devices.
Wire color
To PVS 405D terminal
White
A ‑ (Tx on the RS‑232 port)
Violet
B ‑ (Rx on the RS‑232 port)
Drain wire
G ‑ Ground
Black
To PVS 405D Power Supply
Red
To PVS 405D Power Supply
PVS 405D • Connector Wiring
External Power Supply
(12 VDC, 4 A)
48