Rs-232/Rs-422 Connection; Reset Button; Power Connection - Extron electronics MTPX Series User Manual

Mini twisted pair matrix switcher
Hide thumbs Also See for MTPX Series:
Table of Contents

Advertisement

Installation, cont'd

RS-232/RS-422 connection

h
Figure 2-8 — Remote RS-232/RS-422 connector
N The switcher can support either the RS-232 or RS-422 serial communication

Reset button

i
N Hard reset does not clear the current configuration.

Power connection

j
W The power connector is wired double pole with neutral fusing.
2-8
MTPX Twisted Pair Matrix Switchers • Installation
By default, the audio ties follow the video ties. Audio breakaway, which
can be activated via the front panel or under serial port control, allows you
to select from any one of the audio input sources and route it separately
from its corresponding video source. See chapter 3, "Operation", chapter 4,
"Programmer's Guide", and chapter 5, "Matrix Software", for details.
Remote RS-232/RS-422 connector — Connect a host device, such as a
computer, touch panel control, or RS-232 capable PDA to the switcher via this
9-pin D connector for serial RS-232/RS-422 control (figure 2-8).
Pin
RS-232 Function
1
2
TX
3
RX
1
6
4
5
Gnd
9
5
6
7
8
9
See chapter 4, "Programmer's Guide", for definitions of the SIS commands
(serial commands to control the switcher via this connector) and chapter 5,
"Matrix Software", for details on how to install and use the control software.
protocol, and can operate at 9600, 19200, 38400, or 115200 baud rates.
See "Selecting the rear panel Remote port protocol and baud rate" on page 3-42,
to configure the RS-232/RS-422 port from the front panel.
If desired, connect an MKP 2000 or MKP 3000 remote control panel to the
switcher's RS-232/RS-422 connector. Refer to the MKP 2000 Remote Control
Panel User's Manual or the MKP 3000 User's Manual for details.
Reset button — The Reset button initiates two levels of reset to the
matrix switcher (see "Rear Panel Operations" in chapter 3, "Operation",
for details):
Rear panel (mode 5) system reset — Press and hold the Reset button
while the switcher is running until the Reset LED blinks three times
(approximately 9 seconds), then release the button and push it again.
This reset clears all ties and presets and resets all audio gains to 0 dB.
Hard reset — Press and hold the Reset button while powering up the
switcher to perform all of the mode 5 reset functions and restore the
switcher to the default factory conditions.
AC power connector — Plug a standard IEC power cord into this connector to
connect the switcher to a 100 VAC to 240 VAC, 50 or 60 Hz power source.
RS-422
Function
Not used
Not used
Transmit data
TX–
Transmit data (–)
Receive data
RX–
Receive data (–)
Not used
Not used
Signal ground
Gnd
Signal ground
Not used
Not used
Not used
RX+
Receive data (+)
Not used
TX+
Transmit data (+)
Not used
Not used
RESET