Capacity Control - Toshiba RAS-07PKVP-E Service Manual

Split type
Hide thumbs Also See for RAS-07PKVP-E:
Table of Contents

Advertisement

High Wall, Heat Pump Type
Outdoor fan speed (rpm)
07PAVP-E
10PAVP-E
Tap
07PAVP-ND
10PAVP-ND
f0
0
0
f1
230
230
f2
300
300
f3
350
350
f4
400
400
f5
450
450
f6
500
500
f7
550
550
f8
600
600
f9
650
650
fA
700
700
fB
750
750
fC
750
750
fD
750
800
fE
800
850
fF
800
850
1) The operation command sent from the remote
controller is processed by the indoor unit
controller and transferred to the controller of
the outdoor unit.
2) When strong wind blows at outdoor side, the
operation of air conditioner continues with the
fan motor stopped.
3) Whether the fan is locked or not is detected,
and the operation of air conditioner stops and
an alarm is displayed if the fan is locked.
4) According to each operation mode, by the
conditions of outdoor temperature (TO) and
compressor revolution, the speed of the
outdoor fan shown in the table is selected.
13PAVP-E
16PAVP-E
18PAVP-E
13PAVP-ND
16PAVP-ND
18PAVP-ND
0
0
0
230
230
230
300
300
300
350
350
350
400
400
400
450
450
450
500
500
500
550
550
550
600
600
600
650
650
650
700
700
700
800
800
800
800
800
800
850
850
900
900
900
950
900
900
950

8-5. Capacity Control

The cooling or heating capacity depending on the load
is adjusted.
According to difference between the setup value of
temperature and the room temperature, the capacity is
adjusted by the compressor revolution.
Remote controller
Set temperature (Ts)
Correction of Hz signal
Detection of electromotive force
of compressor motor winding
Detection of motor speed and rotor position
Correction value of Hz signal Operating Hz
Inverter output change
Commutation timing change
Change of compressor speed
1) The difference between set temperature on
remote controller (Ts) and room temperature
(TA) is calculated.
2) According to the temperature difference, the
correction value of Hz signal which determines
the compressor speed is set up.
3) The rotating position and speed of the motor
are detected by the electromotive force
occurred on the motor winding with operation
of the compressor.
4) According to the difference resulted from
comparison of the correction value of Hz signal
with the present operation Hz, the inverter
output and the commutation timing are varied.
5) Change the compressor motor speed by
outputting power to the compressor.
*The contents of control operation are same
in cooling operation and heating operation
38