Advertisement

PORT HOLES IN SHADED
AREA SHOULD BE COVERED
WITH EMBER MATERIAL. NO
OTHER PORT HOLES MAY
COME INTO CONTACT WITH
EMBER MATERIAL.
Figure 12.4
EMBER MATERIAL
Figure 12.5 Placement of Embers
E. Install Refractory
SL-550TRS-IPI-E, SL-550TRS-E, SL-750TRS-IPI-E and
SL-750TRS-E only.
CAUTION
Refractory is fragile! Carefully remove the refractory from the
packaging.
Step 1.
Remove the logs from the fi replace. Place the back wall
refractory centered against the back of the fi replace on
top of the grate tabs. While steadying the back piece
with one hand, place the left refractory against the fi re-
box left wall such that it is against the back refractory
(see Figure 12.6).
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-IPI • 2120-901 Rev. F • 9/08
Figure 12.6
Step 2.
Place the right refractory against the fi rebox right wall such
that it is against the back refractory (see Figure 12.7).
Figure 12.7
Step 3.
Bend left and right refractory retainer tabs to keep side
pieces from tipping (see Figure 12.8).
REFRACTORY
REFRACTORY
RETAINER TAB
RETAINER TAB
Figure 12.8
Step 4.
Install logs according to the install manual.