E. Junction Box Installation
If the box is being wired from the OUTSIDE of
the appliance:
• Remove the cover plate located on the outer
shell - right side (see Figure 10.5).
• Install the supplied Romex™ connector in the
cover plate.
• Feed the necessary length of wire through the con-
nector.
• Make all necessary wire connections and reat-
tach the cover plate to the outer shell.
If the box is being wired from the INSIDE of the
appliance:
• Remove the screw attaching the junction box/
receptacle to the outer shell, rotate the junction
box inward to disengage it from the outer shell
(see Figure 10.5).
• Pull the electrical wires from outside the appli-
ance through this opening into the valve com-
partment.
• Feed the necessary length of wire through the
connector.
• Make all necessary wire connections to the
junction box/receptacle and reassemble the
junction box/receptacle to the outer shell.
F. Wall Switch Installation for Fan (Optional)
If the box is being wired to a wall
mounted switch for use with a fan (See
Figure 10.6):
• The power supply for the appliance
must be brought into a switch box.
• The power can then be supplied from
the switch box to the appliance using
a minimum of 14-3 with ground wire.
• At the switch box connect the black
(hot) wire and red (switch leg) wire to
the wall switch as shown.
• At the appliance connect the black (hot),
white (neutral) and green (ground)
wires to the junction box as shown.
• Add a 1/4 inch insulated female con-
nector to the red (switch leg) wire, route
it through the knockout in the face of
the junction box, and connect to the top
fan switch connector (1/4 inch male) as
shown.
46
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-IPI • 2120-901 Rev. F • 9/08
Figure 10.5 Junction Box Detail
MINIMUM 14-3
WITH GROUND
JUNCTION BOX
Red
Figure 10.6 Junction Box Wired to Wall Switch
Cover Plate
outside firebox
Copper
ground attached
GRN wire
to GRN screw with
inside box
GRN wire
NOTE: Do NOT wire
110VAC to wall switch.
A W G
Red
Black
White
Green
SWITCH BOX
Romex
Connector
14/2WG
SWITCH
Black
White
Green
POWER
SUPP LY WIRE S