The installation must conform with local codes or, in
absence of local codes, the National Gas and Propane
Installation Code CSA B149.1 in Canada, or the National
Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United
States. Suitable for mobile home installation if installed in
accordance with the current standard CAN/CSA Z240MH
Series, for gas equipped mobile homes, in Canada or
ANSI Z223.1 and NFPA 54 in the United States.
As long as the required clearance to combustibles is
maintained, the most desirable and benefi cial location for an appliance is in the center of a building, thereby
allowing the most effi cient use of the heat created. The location of windows, doors and the traffi c fl ow in the
room where the appliance is to be located should be considered. If possible, you should choose a location
where the vent will pass through the house without cutting a fl oor or roof joist.
If the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood
fl ooring, the appliance shall be installed on a metal or wood panel extending the full width and depth.
Some appliances have optional fans or blowers. If an optional fan or blower is installed, the junction box must
be electrically connected and grounded in accordance with local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA 70 National Electrical code in the United States.
The blower power cord must be connected into a properly grounded receptacle. The grounding prong must not
be removed from the cord plug.
2.3

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
Altitude (FT)
Max. Input (BTU/HR)
Max. Output (BTU/HR)
Effi ciency (w/ the fan on)
Min. Inlet Gas Supply Pressure
Max. Inlet Gas Supply Pressure
Manifold Pressure (Under Flow Conditions)
When the appliance is installed at elevations above 4,500ft, and in the absence of specifi c recommendations from
the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000ft. Expansion / contraction noises during heating up and cooling down cycles are normal and to be
expected.
Provided that the clearance to combustibles are achieved, the most desirable and benefi cial location for an
appliance is in the centre of a building, thereby allowing the most effi cient use of the heat created. The location
of windows, doors and the traffi c fl ow in the room where the appliance is to be located should be considered.
If possible, you should choose a location where the vent will pass through the house without cutting a fl oor or
roof joist.
This appliance is approved for closet or recessed installations, as well as for bathroom, bedroom and bed-sit-
ting room installations and is suitable for mobile home installations. The natural gas model can be installed in a
mobile home that is permanently positioned on its site and fueled with natural gas.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use
with other gases, unless a certifi ed kit is used.
W415-0496 / D / 11.05.10
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certified in the U.S.
by the National Fireplace
Institute ® (NFI) as NFI Gas
Specialists
www.nficertified.org
GDS20
NG
0-4,500
20,000
15,600
78%
4.5" Water Column
7" Water Column
3.5" Water Column
4.1A
LP
0-4500
20,000
15,600
78%
11" Water Column
13" Water Column
10" Water Column