D. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).
Combustible Mantels
1/2 in.
Thick Wall
Sheathing
14 in.
MIN.
Figure 5.3 Clearances To Combustible Mantels Or Other
Combustibles Above Appliance
Non-combustible Mantels
1/2 in.
Thick Wall
Sheathing
Figure 5.4 Clearances To Non-Combustible Mantels Or Other
Non-Combustibles Above Appliance
Note: For non-combustible fi replace fi nish material (marble,
stone, etc) specifi cations refer to Section 13.C.
12 in.
MAX.
MEASUREMENT FROM TOP OF
FIREPLACE OPENING
12 in.
MAX.
MEASUREMENT
14 in.
FROM TOP OF
MIN.
FIREPLACE
OPENING
Heatilator • RAVE4013I • 2184-900 Rev. E • 8/09
Combustible Mantel Legs Or Wall Projections
Extending Past The Face Of The Fireplace
Figure 5.5 Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
Non-combustible Mantel Legs Or Wall Projections
Extending Past The Face Of The Fireplace
Figure 5.6 Non-Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
Front Side Finishing Detail
1-9/16 in.
Figure 5.7 Front Side Finishing Detail
2 IN.
MINIMUM
3 FT. MAXIMUM
6 IN.
MINIMUM
3 IN.
UNLIMITED
MINIMUM
7 IN.
1.00 in.
FRAMING
1/2 in. BUILDING MATERIAL