Lubrication System

Engine Oil Capacity
Caution
The vehicle must be parked on a level
ground when checking oil capacity.
Run the engine for 3-5 minutes then stop,
wait about 3-5 more minutes allowing
engine oil to settle before checking the oil
level.
Remove dipstick to check the oil level. If oil level
is below the lower limit mark, add oil to the
specified upper limit mark.
Engine Oil change
Shut off the engine and remove dipstick.
Remove the oil drain plug on the bottom-left of
crankcase to drain oil.
After draining out oil, clean oil plug and its gasket
and reinstall. Replace the gasket if it is damaged.
Torque value: 3.5~4.5 kgf-m
Caution
Warm up the engine. This will make the oil
flow out easily.
Add oil to the specified capacity.
Oil Viscosity: SAE 10W-30, or equivalent
recommended using King-Mate serial oil.
Engine oil capacity: Disassembly:
When checking for oil leak, run the engine at idle
speed for a few minutes, then check oil capacity
with dipstick.
Cleaning the oil strainer
Drain oil from engine, remove the strainer cover,
spring and strainer.
If there is an accumulation on the screen, wash it
off with suitable solvent (recommended using
compressed air to cleaning the foreign).
Check O-ring for damage, replace if necessary.
Reinstall strainer, spring, O-ring and strainer
cover.
Torque value: 1.3~1.7 kgf-m
This chapter Contents
1050cc
Change:
800cc

2. Maintenance Information

Oil drain plug
2-3