7.0 OPTIONAL INSTALLATION

7.1

OPTIONAL BLOWER INSTALLATION

TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH
THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS
COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL
ENSURE THAT THE FAN'S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE
APPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE. DO NOT RUN THE POWER
THE WIRE HARNESS PROVIDED IN THE BLOWER KIT IS A UNIVERSAL HARNESS. WHEN
INSTALLED, ENSURE THAT ANY EXCESS WIRE IS CONTAINED, PREVENTING IT FROM MAKING
7.1.1
Turn off any electrical power to the appliance (if applicable). Open the lower louvred control door.
7.1.2
Locate the vibration reducing pad over the two threaded studs,
piercing 2 holes into the pad. The fan must be installed on the left
hand side of the appliance entirely on the pad.
7.1.3
Slide the fan to the back of the appliance taking care not to
damage the terminals. Position the fan onto the studs and secure
using the lock washers and wing nuts provided. Pull the leads to
the front and right side of the ashpan housing.
7.1.4
Remove the junction box. Use a nut connector to attach the black
wires of the variable speed switch and the power.
7.1.5
Pass the two fan leads and one thermal switch lead through
the junction box
bushing. The thermal
switch is located
inside the outer
shell, just above the
louvre door. Connect
one fan lead to the
thermal switch lead
and the other fan
lead to the white
wire of the variable
speed switch using
nut connectors.
7.1.6
Thread the other
thermal switch
lead through the junction box bushing and connect to the white wire of the power cord using a nut
connector. Secure ground wire (green) to the threaded weld stud located on the junction box wall.
Reposition the junction box. Verify that the wires will not interfere with the fan.
Because the blower is thermally activated, when turned on, it will automatically start approximately 15-
45 minutes after lighting the appliance. Use of the fan increases the output of heat.
Drywall dust will penetrate into the blower bearings causing irreparable damage and must be
prevented from coming into contact with the blower or its compartment. Any damage resulting from this
condition is not covered by the warranty policy.
W415-0676 / A / 06.07.10
WARNING
!
RISK OF FIRE AND ELECTRICAL SHOCK.
VOID THE WARRANTY AND CERTIFICATION.
CORD BENEATH THE APPLIANCE.
CONTACT WITH MOVING OR HOT OBJECTS.
BLOWER
WING NUT &
LOCK WASHER
VIBRATION
REDUCING
PAD
THERMAL
SWITCH
THERMAL SWITCH
FAN
VARIABLE SPEED SWITCH
51.5
BLOWER
POWER
MARETTES
VARIABLE
SPEED
SWITCH
JUNCTION
BOX