Electrical Data; Sound Power - Carrier Deluxe 38YZA Product Data

Deluxe 12 seer split-system heat pump with puron refrigerant
Hide thumbs Also See for Deluxe 38YZA:
Table of Contents

Advertisement

Accessory description and usage (Listed alphabetically) continued
17. Support Feet
Four stick-on plastic feet which raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base; minimizes corrosion.
SUGGESTED USE: Coastal installations.
Windy areas or where debris is normally circulating.
Rooftop installations.
18. Thermostatic Expansion Valve (TXV) — Bi-Flow
A modulating flow control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes
valve, adapter tubes, external equalizer tube.
SUGGESTED USE: A TXV specifically designed for Puron refrigerant is required for all installations.
19. Time-Delay Relay
An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off.
SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. (Refer to ARI Unitary Directory.)
Required for use on all zoning systems.

Electrical data

UNIT SIZE-
SERIES
V-PH
018-31, 32
024-31, 32
030-31, 32
036-31, 32
208-230-1
042-31, 32
048-31, 32
060-31, 32
* Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure.
† Time-delay fuse or Circuit Breaker.
‡ Length shown is as measured 1 way along the wire path between the unit and the service panel for voltage drop not to exceed 2%.
** If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM),
trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26.
If other than uncoated (non-plated), 60° or 75°C (140° or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than
10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).
FLA — Full Load Amps
LRA — Locked Rotor Amps
MCA — Minimum Circuit Amps
RLA — Rated Load Amps
NOTE: Control circuit is 24v on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors
contain internal overload protection.

Sound power

UNIT
SOUND
SIZE–
LEVEL
SERIES
(dBA)
018-31, 32
73
024-31, 32
73
030-31, 32
73
036-31, 32
74
042-31, 32
73
048-31, 32
76
060-31, 32
76
Note: Tested in accordance with ARI Standard 270-95. (Not listed with ARI).
6
OPER VOLTS*
Max
Min
LRA
51.0
61.0
72.5
253
197
83.0
104.0
109.0
158.0
A – WEIGHTED SOUND POWER LEVELS (dBA) WITHIN OCTAVE BAND SHOWN
125
250
44.9
51.4
47.0
59.5
50.0
53.5
50.0
56.0
54.5
61.5
50.0
61.5
51.0
62.0
COMPR
FAN
RLA
FLA
10.3
0.5
13.5
0.8
14.7
1.1
19.3
1.1
21.1
1.1
20.5
1.4
27.6
1.4
500
1000
61.3
62.0
62.5
61.0
61.0
63.5
61.0
67.0
64.0
61.5
66.5
65.5
65.0
66.5
MIN
MAX
WIRE
LENGTH
SIZE
(Ft)
MCA
60°C/75°C**
60°C/75°C‡
13.4
14/14
59/56
17.7
14/14
44/42
19.5
14/14
39/37
25.2
12/12
50/48
27.5
10/10
71/68
27.0
10/10
74/70
35.9
8/8
86/82
2000
4000
57.7
52.5
57.5
53.0
56.5
50.0
60.0
54.0
59.5
55.5
63.5
60.5
62.5
60.5
MAX FUSE†
OR
CKT BKR
AMPS
20
25
30
35
40
40
60
8000
44.4
45.0
41.0
46.5
47.0
51.5
54.5