Heat pump heating performance

INDOOR
AIR
–3
Capacity
Total
(MBtuh)
Pwr
EDB
CFM
Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW†
525
6.79 6.25 1.28 8.59 7.90 1.33 10.4 9.47 1.36 12.4 11.0 1.40 14.6 13.3 1.45 17.2 17.2 1.52 20.1 20.1 1.60 23.5 23.5 1.71
65
600
6.92 6.36 1.29 8.71 8.01 1.33 10.5 9.57 1.35 12.5 11.1 1.38 14.8 13.5 1.42 17.4 17.4 1.48 20.3 20.3 1.55 23.8 23.8 1.66
675
7.03 6.47 1.30 8.81 8.10 1.33 10.6 9.68 1.35 12.6 11.2 1.38 14.9 13.6 1.41 17.6 17.6 1.46 20.5 20.5 1.53 24.1 24.1 1.64
525
6.58 6.06 1.36 8.43 7.74 1.41 10.3 9.37 1.46 12.2 10.9 1.50 14.5 13.2 1.55 17.0 17.0 1.62 19.8 19.8 1.70 23.2 23.2 1.82
70
600
6.71 6.17 1.37 8.56 7.87 1.41 10.4 9.48 1.45 12.4 11.0 1.48 14.6 13.3 1.52 17.2 17.2 1.58 20.1 20.1 1.65 23.5 23.5 1.76
675
6.83 6.28 1.38 8.68 7.97 1.42 10.5 9.58 1.45 12.5 11.1 1.47 14.8 13.4 1.51 17.4 17.4 1.56 20.3 20.3 1.63 23.7 23.7 1.73
525
6.35 5.84 1.45 8.24 7.57 1.51 10.2 9.26 1.56 12.1 10.8 1.61 14.3 13.0 1.66 16.8 16.8 1.73 19.6 19.6 1.81 22.9 22.9 1.93
75
600
6.48 5.96 1.46 8.38 7.70 1.50 10.3 9.36 1.55 12.3 10.9 1.59 14.5 13.2 1.63 17.0 17.0 1.69 19.8 19.8 1.76 23.2 23.2 1.87
675
6.60 6.07 1.47 8.50 7.81 1.51 10.4 9.47 1.55 12.4 11.0 1.57 14.6 13.3 1.61 17.2 17.2 1.66 20.0 20.0 1.73 23.4 23.4 1.84
Indoor
Section
Size
CC5A/CD5AA
024
CC5A/CD5AW
024
CE3AA
024
CF5AA
024
CK3BA
024
CK5A/CK5BA
024
CK5A/CK5BW
024
F(A,B)4(A,B)N(F,C)
024
FC4(B,C)NF
024
FF1DNA
024
FG3AAA
024
FK4(C,D)NF
002
FV4(A,B)NF
002
FX4(A,B)NF
018
COILS + 58CV(A,X)070-12 VARIABLE SPEED FURNACE
CC5A/CD5AA
024
See notes on pg. 30.
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
7
17
Capacity
Total
Capacity
Total
(MBtuh)
Pwr
(MBtuh)
Pwr
38YZA018-31, 32 Outdoor Section With FX4(A,B)NF018 Indoor Section
Multipliers for Determining the Performance With Other Indoor Sections
Heating
Capacity
Power
0.96
1.03
0.93
1.02
0.97
0.90
0.95
1.01
1.00
0.99
0.99
0.99
0.99
0.99
0.99
1.00
0.99
1.00
0.99
1.01
0.99
1.06
0.98
1.03
0.98
1.03
1.00
1.00
0.94
0.91
27
37
Capacity
Total
Capacity
Total
(MBtuh)
Pwr
(MBtuh)
Pwr
Indoor
Section
CC5A/CD5AW
CE3AA
CK3BA
CK5A/CK5BA
COILS + 58MVP060-14 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
CE3AA
CK3BA
CK5A/CK5BA
CK5A/CK5BW
COILS + 58MVP080-14 VARIABLE SPEED FURNACE
CC5A/CD5AW
CE3AA
47
57
Capacity
Total
Capacity
Total
(MBtuh)
Pwr
(MBtuh)
Pwr
Heating
Size
Capacity
024
0.94
024
0.94
024
0.96
024
0.96
024
0.92
024
0.94
024
0.96
024
0.98
024
0.98
024
0.98
024
0.95
024
0.96
67
Capacity
Total
(MBtuh)
Pwr
Power
0.90
0.91
0.88
0.88
0.94
0.95
0.95
0.91
0.91
0.91
0.95
0.95
23

Hide quick links: