Carrier Deluxe 38YZA Product Data page 14

Deluxe 12 seer split-system heat pump with puron refrigerant
Hide thumbs Also See for Deluxe 38YZA:
Table of Contents

Advertisement

Combination ratings* continued
UNIT SIZE-
INDOOR
SERIES
UNIT
CC5A/CD5AA060
CC5A/CD5AW060
CK3BA060
CK5A/CK5BA060
CK5A/CK5BX060
048-31, 32
CC5A/CD5AA060
CC5A/CD5AW060
CK3BA060
CK5A/CK5BA060
CK5A/CK5BX060
FX4(A,B)NB060†
CC5A/CD5AW060
CK5AX060
FB4(A,B)NB070
FC4(B,C)NB070
FV4(A,B)NB006
060-31, 32
40FK(A,B)/FK4(C,D)NB006 1750
CD5PX060
CC5A/CD5AW060
* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard: 80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit.
High-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.
Low-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 17°F (–9°C) db 15°F (–10°C) wb air entering outdoor unit.
† Outdoor section/indoor section combination tested in accordance with DOE test procedures for heat pumps. Ratings for other combinations are determined
under DOE computer simulation procedures.
‡ Based on computer simulation. TXV must be Puron compatible and hard shutoff type.
** In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use
either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR.
†† Indoor Airflow
‡‡ Must replace Factory-supplied R-22 TXV with Puron TXV.
SEER — Seasonal Energy Efficiency Ratio
COP — Coefficient of Performance
HSPF — Heating Seasonal Performance Factor
EER — Energy Efficiency Ratio
14
Seasonal Efficiency SEER
Factory-
Supplied
Enhance-
Standard
CFM††
TC
ment
COILS + 58MVP100-20 VARIABLE SPEED FURNACE
1400
44,500
TDR
1400
45,000
TDR
1400
44,500
TDR
1400
44,500
TDR
1400
45,000
TDR
COILS + 58MVP120-20 VARIABLE SPEED FURNACE
1400
44,500
TDR
1400
45,000
TDR
1400
44,500
TDR
1400
44,500
TDR
1400
45,000
TDR
1750
57,000
TXV&TDR
1750
56,000
NONE
1750
56,500
NONE
1750
57,000
TDR
1750
57,000
TDR‡‡
1750
57,500
TXV&TDR
58,000
TDR‡‡
COILS + 58CV(A,X)110-22 VARIABLE SPEED FURNACE
1750
56,500
TDR&TXV
COILS + 58CV(A,X)155-22 VARIABLE SPEED FURNACE
1750
56,000
TDR
TC — Total Capacity (Btuh)
TDR — Time-Delay Relay
TXV — Thermostatic Expansion Valve
ARI STANDARD RATINGS*
Cooling
Field-Supplied
Accessory‡
Puron
Puron TXV
Rating
TXV
& TDR**
EER
13.00
11.25
13.00
11.45
13.00
11.25
13.00
11.25
13.00
11.45
13.00
11.30
13.00
11.70
13.00
11.30
13.00
11.30
13.00
11.70
12.00
10.20
12.00
10.45
12.00
10.55
12.00
10.20
12.00
10.20
12.50
10.75
12.50
10.75
12.3
10.5
12.3
10.55
Heating
High-Temp
Low-Temp
TC
COP
TC
COP
47,500
3.50
27,800
2.40
48,000
3.54
27,800
2.44
47,500
3.50
27,800
2.40
47,500
3.50
27,800
2.40
48,000
3.54
27,800
2.44
47,500
3.52
27,800
2.40
48,000
3.54
27,800
2.42
47,500
3.52
27,800
2.40
47,500
3.52
27,800
2.40
48,000
3.54
27,800
2.42
60,000
3.44
37,800
2.46
58,000
3.26
36,800
2.42
59,000
3.44
37,000
2.50
60,000
3.44
37,800
2.46
60,000
3.44
37,800
2.46
60,000
3.56
37,000
2.54
59,500
3.56
37,000
2.54
59,000
3.52
37,200
2.52
58,500
3.28
36,600
2.44
HSPF
8.00
8.20
8.00
8.00
8.20
8.00
8.20
8.00
8.00
8.20
7.80
7.60
7.80
7.80
7.80
8.00
8.00
8
7.6