Heat pump heating performance continued
INDOOR
AIR
–3
Total
Capacity
Pow-
(MBtuh)
er
EDB CFM
Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW†
1750 26.3 24.2 4.04 32.5 29.9 4.19 38.7 35.3 4.33 45.2 40.1 4.46 52.9 48.1 4.63 61.7 61.7 4.83 72.3 72.3 5.11 84.4 84.4 5.41
65
2000 26.8 24.7 4.10 33.0 30.3 4.23 39.2 35.7 4.35 45.8 40.6 4.46 53.5 48.7 4.61 62.6 62.6 4.80 73.4 73.4 5.06 84.1 84.1 5.27
2250 27.3 25.1 4.17 33.5 30.8 4.29 39.6 36.1 4.39 46.3 41.1 4.49 54.2 49.3 4.62 63.3 63.3 4.80 74.4 74.4 5.02 84.0 84.0 5.20
1750 25.3 23.3 4.20 31.8 29.2 4.38 38.3 34.9 4.55 44.7 39.7 4.69 52.2 47.5 4.86 60.9 60.9 5.08 71.3 71.3 5.37 83.2 83.2 5.68
70
2000 25.9 23.8 4.26 32.4 29.8 4.43 38.8 35.4 4.57 45.3 40.2 4.69 52.9 48.2 4.84 61.7 61.7 5.04 72.4 72.4 5.30 84.3 84.3 5.57
2250 26.4 24.3 4.34 32.9 30.2 4.48 39.3 35.8 4.61 45.8 40.7 4.71 53.5 48.7 4.85 62.4 62.4 5.03 73.2 73.2 5.28 84.1 84.1 5.49
1750 24.2 22.3 4.34 31.0 28.5 4.58 37.8 34.4 4.77 44.3 39.3 4.94 51.7 47.0 5.12 60.1 60.1 5.34 70.3 70.3 5.63 82.2 82.2 5.98
75
2000 24.8 22.8 4.41 31.6 29.1 4.62 38.3 35.0 4.79 44.8 39.8 4.93 52.3 47.6 5.09 60.9 60.9 5.29 71.3 71.3 5.56 83.1 83.1 5.84
2250 25.4 23.3 4.49 32.2 29.6 4.68 38.9 35.4 4.83 45.3 40.3 4.95 52.9 48.1 5.09 61.7 61.7 5.28 72.2 72.2 5.53 83.5 83.5 5.77
Indoor
Section
Size
CC5A/CD5AW
CK5A/CK5BX
FB4(A,B)NB
FC4(B,C)NB
FV4(A,B)NB
FX4(A,B)NB
NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* The Btuh heating capacity values shown are net integrated'' values from which the defrost effect has been subtracted. The Btuh heating from supplement
heaters should be added to those values to obtain total system capacity.
† The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to
obtain total system kilowatts.
EDB—Entering Dry Bulb
30
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
7
17
Total
Capacity
Pow-
Capacity
(MBtuh)
er
(MBtuh)
38YZA060-31, 32 Outdoor Section With FX4(A,B)NB060 Indoor Section
Multipliers for Determining the Performance With Other Indoor Sections.
Heating
Capacity
060
0.97
060
0.98
070
1.00
070
1.00
006
1.00
060
1.00
27
37
Total
Total
Pow-
Capacity
Pow-
Capacity
er
(MBtuh)
er
(MBtuh)
Indoor
Power
Section
1.08
40FK(A,B)/FK4(C,D)NB
1.04
COILS + 58CV(A,X)110-22 VARIABLE SPEED FURNACE
1.03
CD5PX
1.03
COILS + 58CV(A,X)155-22 VARIABLE SPEED FURNACE
1.00
CC5A/CD5AW
1.03
47
57
Total
Total
Pow-
Capacity
Pow-
Capacity
er
(MBtuh)
er
(MBtuh)
Size
Capacity
006
0.99
060
0.98
060
0.98
67
Total
Total
Pow-
Capacity
Pow-
er
(MBtuh)
er
Heating
Power
0.99
1.00
1.06