Physical data and electrical data

Table I: Physical data
61AF
Operating weight*
Standard unit (without hydronic kit)
Standard unit (plus hydronic module option)
Sound levels
Sound power level 10-12 W**
Sound pressure level at 10 m***
Compressor
Quantity
Number of capacity stages
Refrigerant
Charge
Capacity control
Minimum capacity
Condenser
Water volume
Max. water-side operating pressure without hydronic module
Max. water-side operating pressure with hydronic module
Fan
Quantity
Total air flow (high speed)
Speed
Evaporator
Pump
Water connections with/without hydronic module
Connection Type (M male/ F female)
Connections
Nominal diameter
* Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate.
** In accordance with ISO 9614-1, for information only.
*** For information, calculated from the sound power level Lw(A) in free field over reflecting plane
Table II: Electrical data
61AF - standard unit
Power circuit
Nominal power supply
Voltage range
Control circuit supply
Maximum start-up current (Un)*
Standard unit
Unit with electronic starter option
Unit power factor at maximum capacity**
Maximum unit power input**
Nominal unit current draw***
Maximum unit current draw (Un)****
Maximum unit current draw (Un-10%)†
*
Maximum instantaneous start-up current (maximum operating current of the pump + fan current + locked rotor current of the compressor).
** Power input, compressor and fan, at the unit operating limits (saturated suction temperature 10°C, saturated condensing temperature 65°C)
and nominal voltage of 400 V (data given on the unit nameplate).
*** Standardised Eurovent conditions: condenser entering/leaving water temperature = 40°C/45°C, outside air temperature db/wb = 7°C/6°C.
****Maximum unit operating current at maximum unit power input and 400 V (values given on the unit nameplate) for tri phase and 230V for
mono phase.
Maximum unit operating current at maximum unit power input and 360 V for tri phase and 207 V for mono phase.
GB - 2
kg
kg
dB(A)
dB(A)
kg
%
l
kPa
kPa
l/s
r/min
inch
mm
Without PUMP
014X7
014X9
V-ph-Hz
230-1-50
400-3-50
V
207-253
360-440
24 V, via internal transformer
A
-
66
A
47
-
0,82
0,82
kW
6,4
5,9
A
22,9
7,9
A
30,7
10,8
A
36,4
11,9
014-7
014-9
159
159
169
169
71
71
43
43
Hermetic scroll 48.3 r/s
1
1
1
1
R-407C
R-407C
4,0
4,0
Pro-Dialog+
100
100
Direct-expansion plate heat exchanger
3,7
3,7
300
300
300
300
Two, axial type with two speeds
2
2
2090
2090
690
690
Grooved copper tubes and aluminium fins
One, three-speed
F
F
1
1
25
25
019X9
014H7
400-3-50
230-1-50
360-440
207-253
24 V, via internal transformer
102
-
-
48
0,82
0,82
8,8
6,6
12,4
23,7
16,0
31,5
16,6
36,4
019-9
206
216
72
44
1
1
R-407C
8,0
100
3,9
400
400
2
2000
880
M, M
1 IN, 1 1/4 OUT
25 IN, 32 OUT
With PUMP
014H9
019H9
400-3-50
400-3-50
360-440
360-440
67
104
-
-
0,82
0,82
6,1
9,2
7,9
12,4
10,8
16,0
11,9
16,6