Bryant 352AAV Installation, Start-Up, And Operating Instructions Manual page 40

Deluxe 4-way multipoise 2-stage condensing gas furnace
Table of Contents

Advertisement

ALTITUDE
UNIT SIZE
FT (M)
(BTUH)
60,000
80,000
7001 to
8000
(2134 to
100,000
2438)‡
120,000
60,000
80,000
8001 to
9000
(2438 to
100,000
2743)‡
120,000
60,000
80,000
9001 to
10,000
(2743 to
3048)‡
100,000
120,000
*Disk usage --- Unless otherwise specified, use perforated disk assembly (factory-supplied in loose parts bag). If one disk is stated, separate 2 halves of
perforated disk assembly and use shouldered disk half. When using shouldered disk half, install screen side toward inlet box.
†Wide radius elbow.
‡Vent sizing for Canadian installations over 4500 ft (1370 M) above sea level are subject to acceptance by the local authorities having jurisdiction. NA---Not
Allowed; pressure switch will not make.
NOTES:
1. Do not use pipe size greater than those specified in table or incomplete combustion, flame disturbance, or flame sense lockout may occur.
2. Size both the combustion---air and vent pipe independently, then use the larger diameter for both pipes.
3. Assume two 45° elbows equal one 90° elbow. Wide radius elbows are desirable and may be required in some cases.
4. Elbows and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.
5. The minimum pipe length is 5 ft (2 M) for all applications.
6. Use 3-in. (76 mm) diameter vent termination kit for installations requiring 4-in. (102 mm) diameter pipe.
Table 13—Maximum Allowable Pipe Length - - Ft. (M) (Continued)
DIRECT VENT (2-PIPE)
ONLY
TERMINATIO
PIPE DIA
N TYPE
(IN.)*
1---1/2 (38)
2 Pipe or 2-in.
(51 mm)
Concentric
2 (51)
2 (51)
2 Pipe or 2-in.
(51 mm)
Concentric
2---1/2 (64)
2---1/2 (64)
2 Pipe or 3-in.
(76 mm)
Concentric
3 (76)
3 (76)† no disk
2 Pipe or 3-in.
(76 mm)
NA
Concentric
4† no disk
1---1/2 (38)
2 Pipe or 2-in.
(51 mm)
Concentric
2 (51)
2 (51)
2 Pipe or 2-in.
(51 mm)
Concentric
2---1/2 (64)
2---1/2 (64)
2 Pipe or 3-in.
(76 mm)
Concentric
3 (76)
3 (76)† no disk
2 Pipe or 3-in.
NA
(76 mm)
Concentric
4† no disk
2 Pipe or 2-in.
(51 mm)
2 (51)
Concentric
2 (51)
2 Pipe or 2-in.
(51 mm)
Concentric
2---1/2 (64)
2---1/2 (64)
2 Pipe or 3-in.
(76 mm)
Concentric
3 (76)
NA
2 Pipe or 3-in.
(76 mm)
Concentric
4† no disk
NON-DIRE
CT VENT
NUMBER OF 90° ELBOWS
(1-PIPE)
ONLY
PIPE DIA
1
2
(IN.)*
12
7
1---1/2 (38)
(3.6)
(2.1)
53
48
2 (51)
(16.1)
(14.6)
36
31
2 (51)
(10.9)
(9.4)
66
65
2---1/2 (64)
(20.1)
(19.8)
25
17
2---1/2 (64)
(7.6)
(5.1)
63
58
3 (76)
(19.2)
(17.6)
20
13
NA
(6.0)
(3.9)
46
44
3 (76)†
(14.0)
(13.4)
61
56
4† no disk
(18.5)
(17.0)
11
6
1---1/2 (38)
(3.3)
(1.8)
49
44
2 (51)
(14.9)
(13.4)
33
28
2 (51)
(10.0)
(8.5)
62
60
2---1/2 (64)
(18.8)
(18.2)
23
15
2---1/2 (64)
(7.0)
(4.6)
59
54
3 (76)
(17.9)
(16.4)
10
NA
NA
(3.0)
43
41
3 (76)†
(13.1)
(12.4)
35
30
4† no disk
(10.6)
(9.1)
45
40
2 (51)
(13.7)
(12.1)
30
25
2 (51)
(9.1)
(7.6)
57
55
2---1/2 (64)
(17.3)
(16.7)
21
13
2---1/2 (64)
(6.4)
(3.9)
54
49
3 (76)
(16.4)
(14.9)
39
37
3 (76)†
(11.8)
(11.2)
10
5
4† no disk
(3.0)
(1.5)
40
3
4
5
6
NA
NA
NA
NA
46
41
40
38
(14.0)
(12.4)
(12.1)
(11.5)
19
14
12
NA
(5.7)
(4.2)
(3.6)
63
62
60
59
(19.2)
(18.8)
(18.2)
(17.9)
8
7
NA
NA
(2.4)
(2.1)
53
48
43
38
(16.1)
(14.6)
(13.1)
(11.5)
7
NA
NA
NA
(2.1)
43
41
40
38
(13.1)
(12.4)
(12.1)
(11.5)
51
46
41
36
(15.5)
(14.0)
(12.4)
(10.9)
NA
NA
NA
NA
42
37
35
34
(12.8)
(11.2)
(10.6)
(10.3)
17
12
10
NA
(5.1)
(3.6)
(3.0)
58
56
55
53
(17.6)
(17.0)
(16.7)
(16.1)
7
5
NA
NA
(2.1)
(1.5)
49
44
39
34
(14.9)
(13.4)
(11.8)
(10.3)
NA
NA
NA
NA
39
37
35
34
(11.8)
(11.2)
(10.6)
(10.3)
25
20
15
10
(7.6)
(6.1)
(4.6)
(3.0)
38
33
31
29
(11.5)
(10.0)
(9.4)
(8.8)
14
9
7
NA
(4.2)
(2.7)
(2.1)
53
51
49
47
(16.1)
(15.5)
(14.9)
(14.3)
5
NA
NA
NA
(1.5)
44
39
34
29
(13.4)
(11.8)
(10.3)
(8.8)
35
33
31
29
(10.6)
(10.0)
(9.4)
(8.8)
NA
NA
NA
NA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents