Measuring Vent Lengths - Lopi Sturbridge Owner's Manual

Direct vent freestanding stove
Hide thumbs Also See for Sturbridge:
Table of Contents

Advertisement

Installation
Measuring
Vent Lengths
Elbows add 3" (75 mm) to the
length of the vent system.
Travis Industries
(for qualified installers only)
Side
View
9-5/8"
(245 mm)
3" (75 mm)
1-1/2" (37 mm)
Vent sections overlap each
other by 1-1/2" (37 mm)
Vent Length
1-1/2"
(3', 4', etc.)
(37 mm)
(910, 1210 mm)
1 0 0 - 0 1 1 4 2
Vent Horizontal Run
(measure from the closest
edge of the starter section to
the end of the termination)
Vent Height is
calculated to the
top of the vent on
horizontal
terminations and
to the top of the
termination on
vertical
terminations.
Vent
Height
1 3
12-3/8" (310 mm) tall
with 1-1/2" (37 mm)
of overlap
8-3/4" (220 mm) wide
with 1-1/2" (37 mm)
to 3-3/8" (85 mm) of
overlap
4 0 2 0 9 1 7