Lopi Sturbridge Owner's Manual page 33

Direct vent freestanding stove
Hide thumbs Also See for Sturbridge:
Table of Contents

Advertisement

Optional Equipment
5
Remove the regulator from the front of the gas control valve. Replace with the propane regulator,
using the new gasket and screws included with the regulator. NOTE: Leak test this area after
the heater is installed, gas is connected, and the main burner is lit.
Remove and discard the three screws using a
slotted screwdriver of Torx T-20.
Slotted
Screwdriver
(or T-20 Torx)
6
Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-
test all gas connections and the gas control valve. Check the pilot. Adjust if necessary.
WARNING:
When lighting or re-lighting the pilot, the glass must be removed (see
page 19).
To adjust the pilot flame, turn this screw (NOTE: if totally
unscrewed gas will come out of this port). Clockwise
lowers the flame while counter-clockwise raises it.
7
Install the log set (see page 20).
8
Replace the glass (see page 19).
Travis Industries
a
b
Remove and discard the
regulator, diaphram, spring
and center post.
Standard
Screwdriver
1 0 0 - 0 1 1 4 2
(for qualified installers only)
c
Install the LP regulator. Use the screws
included with the LP regulator. Tighten to
approximately 25 Lbs. torque.
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
Slotted
Screwdriver
(or T-20 Torx)
d
Place the LP label on top of
the control cover near the gas
control valve.
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
down as necessary.
3 3