Vertical; Through The Wall & Vertical - Quadra-Fire SANTAFE-B1 Owner's Manual

Fireplace
Hide thumbs Also See for SANTAFE-B1:
Table of Contents

Advertisement

R
C. Vertical
Flashing
Firestop
Ceiling Support
6 in.
(152mm)
Min.
Noncombustible Hearth Pad
Figure 14.1
D. Through The Wall & Vertical
Page 14
Rain Cap
24 in. (610mm) Minimum
6 in. (152mm) Class A
Chimney Connector
Adapter
3 in. (76mm) Min.
6 in. (152mm) Flue
Connector
3 in. to 6 in.
(76-152mm)
Top Vent Kit
Cleanout Cover
2 in. (51mm) minimum
6 in. (152mm)
minimum
Figure 14.2
7001-142C
Santa Fe Pellet Stove
We recommend a minimum of 60 in.
(1524mm) vertical, however above the
eave is preferred.
Both installations are approved for mobile
home installations. Must use 3 or 4 inch (76
to 102mm) "L" or "PL" listed pellet venting
or listed double wall pipe and Quadra-Fire
Outside Air Kit in mobile homes. Single
wall pipe is approved for residential instal-
lations only.
Rain Cap
Flashing
24 in. (610mm) minimum
Support Bracket
every 60 in. (1524mm)
Wall Thimble
Cleanout Cover
Noncombustible Hearth Pad
Tee