Vertical Into Existing Class A Chimney; Through The Wall & Vertical - Exterior; Vertical - Interior - Typical Installation - Quadra-Fire MT VERNON E2-C Installation Manual

Mt. vernon e2 pellet appliance
Table of Contents

Advertisement

MT VERNON E2-C
B. Vertical into Existing Class A Chimney
Flashing
Firestop
Ceiling Support
6 in
[152mm]
Min
Non-combustible Hearth Pad
Figure 18.1
C. Through The Wall & Vertical - Exterior
2 in [51mm] min
6 in
[152mm]
Min
Figure 18.2
18
Rain Cap
12 in. [305mm] Min
6 in. [152mm] Class A
Chimney Connector
Adapter
3 in [76mm] Min
3 to 6 in [76 to 152mm]
Offset Adapter
3 to 3 in
[76-76mm]
Top Vent Kit
Clean-out Cover
Rain
Cap
12 in
Flashing
[305 mm]
Minimum
Support
Bracket
every 60 in
[1524mm]
Wall Thimble
Tee
Clean-out
Cover
Non-combustible Hearth Pad
All three installations are approved for mobile home installa-
tions. Must use 3 or 4 inch (76 to 102mm) "L" or "PL" Listed
pellet venting or Listed double wall pipe and Quadra-Fire
Outside Air Kit in mobile homes. Single wall pipe is approved
for residential installations only.
*NOTE: Clearance to combustibles are for standard pellet
pipe. If pellet pipe manufacturer allows reduced clearances
to their pipe, reduced clearances are allowed.
A chimney connector shall not pass through an attic or
roof space, closet or similar concealed space, or a floor or
ceiling.
D. Vertical - Interior - Typical Installation
Firestop
6 in
[152mm]
Min
Figure 18.3
7080-162B
NOTE:
Rain
Cap
12 in
[305 mm]
Flashing
Minimum
3 in [76mm] Min
3 to 3 in
[76 to 76mm]
Top Vent Kit
Clean-out Cover
Non-combustible Hearth Pad
October 12, 2017

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents