2.9.
The hazard flasher draws constant hot through
the red wire with white trace. See Figure 2.9.
Headlight
switch
Figure 2.9
When the contacts are closed (hazard switch
ON), power is passed to the hazard lights via
flasher relay through the blue wire with white
trace.
The hazard circuit extends beyond the lights,
back to the instrument panel, illuminating
arrows: pin #10 = left arrow Pin #21 = right
arrow.
The headlight switch gets power from the red
wire with black trace when the key switch is ON.
When the contacts are closed (headlight switch
ON), power is passed to the headlights through
the blue wire.
The headlight circuit extends beyond the lights,
to the instrument panel (pin # 3) where it illumi-
nates a headlight indicator.
Not all Series 5000 tractors are equipped with
hazard flashers.
The female spade connectors are color coded:
Red for the Hazard circuit
light circuit.
Hazard flasher
switch
and
Blue for the Head-
Domestic Compact Electrical Systems
2.10. The PTO switch is more complex.
See Figure 2.10.
PTO switch
The PTO switch contains two sets of contacts:
one in the starter circuit, and the other in the
engine shut-down and PTO circuits.
The orange wire (starter circuit) brings power
form the key switch in the START position.
If the PTO switch is turned OFF, the contacts
close, passing power to the orange and black
wire.
The orange and black wire conducts power to
the brake switch.
The red wires with black traces conduct power to
the second set of contacts within the PTO switch
when the key switch is ON.
If the PTO switch is ON, contact is made to the
yellow wire with white trace, providing power to
the common terminal on the PTO relay
If the PTO switch is OFF, contact is made to the
plain yellow wire, leading to the brake switch.
76
Figure 2.10

Advertisement