T e s t
Press
Mode
t01
Start/
Display defi nes model id (01-03). Always displays"---" when control
Pause
board replaced. Proper model must be set when control board
replaced. Rotate knob until desired selection is displayed (01-03),
then press and hold Start/Pause until beep.
t02
Start/
Displays the most recent error code. (E00=none) Repeat pressing
Pause
Start/Pause to display up to previous 10 error codes. Press and hold
Start/Pause to clear all error codes. (Will then display E00.)
t03
Start/
Displays software revision numbers. Press Start/Pause to alternate
Pause
between COD (Control software version), EE (eeprom version), and
InV (Inverter software version).
t04
Start/
Displays and tests loops on lighting of LED'S and cycle lights.
Pause
Buttons beep when pressed.
t05
Start/
Displays P and operates pump for 60 seconds, then returns to t05.
Pause
t06
Start/
Water level control test. Pump runs and displays E at start (no
Pause
water in tub). Press Start/Pause to advance. Water valve begins fi ll.
Displays F when reaches FOAM level. Displays nl when reaches
MAIN level, and briefl y displays oF when reaches overfl ow level,
then pumps water out. Displays E when empty.
t07
Start/
Water heater/thermistor test. (Note: Main level switch must be
Pause
functional.) Fills with water to main level, then operates heater
for up to 5 minutes. Displays temperature of water, as heated, in
degrees F. After 5 minutes, water pumps out, then returns to t07.
t08
Start/
Water valve test. Displays hOt and pump runs. Fills with hot water.
Pause
Maximum level is main level switch setting. Pumps out water and
returns to t08.
t09
Start/
Water valve test. Displays Cld and pump runs. Fills with cold water.
Pause
Maximum level is main level switch setting. Pumps out water and
returns to t09.
t10
Start/
Tumble test. Displays tt. Wash basket spins in one direction for 5
Pause
seconds, pauses, then spins in the opposite direction for 5 seconds.
Repeats until exit initiated. (Note: Beginning direction is random.)
t11
Start/
Spin speed-low spin/high spin test. Display shows rpm. Pump runs,
Pause
displays 0, then wash basket ramps to 400 rpm. Press Start/Pause
a second time to ramp to 1000 rpm. (May display 999 or 0 for 1000
rpm.) Then motor is unpowered, displays 0, pump runs, and returns
to t11.
t12
Start/
Dispenser motor/mechanism test. Press Start/Pause to advance.
Pause
Displays Pdt and fi lls via prewash compartment. Displays
ddt and fi lls via wash compartment. Displays bdt and fi lls via
bleach compartment. Displays Fdt and fi lls via fabric softener
compartment. (Note: If main level reached during test, dispenser
operation stops, pump runs, and returns to t12.)
t13
Start/
EOL test sequence. Not used for service.
Pause
t14
Start/
Spin speed ramp up test. Display shows rpm. Pump runs, displays
Pause
0, then wash basket ramps to 100 rpm, pauses, ramps to 350 rpm,
pauses, then ramps to and holds at 1000 rpm. (May display 999 or
0 for 1000 rpm.)
Displays
– 52 –
Exit
Press Power.
Returns to t01
Press Power.
Returns to t02
Press Power.
Returns to t03
Press Power.
Returns to t04
Press Power.
Returns to t05
Press Power.
Pump runs.
Returns to t06
Press Power.
Pump runs.
Returns to t07
Press Power.
Pump runs.
Returns to t08
Press Power.
Pump runs.
Returns to t09
Press Power.
Pump runs.
Returns to t10
Press Power.
Pump runs.
Returns to t11
Press Power.
Pump runs.
Returns to t12
Press Power.
Returns to t13
Press Power.
Pump runs.
Returns to t14