Chapter 3
Managing Linksys 900 Series IP Phones
Step 4
Select yes from the Unit 1 Enable pull-down selection list.
If you have installed two SPA932 units, also select yes from the Unit 2 Enable pull-down
selection list.
Step 5
Make sure that no is selected on the Test Mode Enable selection list.
This option, which is useful for testing the SPA932, is disabled by default. You cannot
complete the software configuration for the SPA932 if this option is enabled.
Step 6
Complete the configuration required for whichever SIP proxy servers that you selected.
You need the following information to complete the SPA932 configuration:
Server IP address (or hostname if supported)
Phone and/or extension or user identifier
For more information about configuring the SIP proxy server, refer to the
Proxy Server" section on page
Step 7
For each extension or user that you want to monitor using the SPA932, enter the configuration script in
the appropriate field for each key.
Note
The configuration script is composed of the following keywords, followed by an equal sign (=)
and separated by semicolons (;):
fnc—defines which of the following functions are enabled for the specified key (separate more than
one function with a plus sign (+):
sub—Use this keyword to identify the phones to be monitored.
usr —Use this keyword to identify the specific users or extensions to be monitored.
nme—(optional) Use this field with the SPA9000 to identify any alias that has been assigned to the
extension in the SPA900 Series phone configuration.
vid—(optional) Use this field to identify the SPA962 extension to use with the monitored list
specified by the sub= keyword, when more than one BLF monitored list is configured on the SIP
proxy server. The possible values are 1 to 6, corresponding to each of the six extensions available
on the SPA962.
Note
Broadsoft Syntax
The following is an example entry for a Broadsoft server:
fnc=enabled_functions;sub=blf_list_uri@broadsoft;usr=dn@broadsoft
Replace the variables (in italics), as follows:
Document Version 3.1
You can identify the user or extension number in the space provided next to each key before
proceeding. This will help ensure that you enter the correct information in each field.
blf—busy lamp field function used for monitoring line activity
sd—speed dial function
cp—call pickup (if supported by the SIP proxy server)
You only need to use the vid= keyword in the first entry assigned to each SPA962 extension.
Subsequent keys will use the same extension.
3-9.
Linksys 900 Series IP Phone Administrator Guide
Using the SPA932 (Sidecar) with the SPA962