D. Junction Box Installation
If the box is being wired from the OUTSIDE of the
appliance:
• Remove the cover plate located on the outer shell
right side (see Figure 10.3).
• Install the supplied Romex™ connector in the cover
plate.
• Feed the necessary length of wire through the
connector.
• Make all necessary wire connections and reattach
the cover plate to the outer shell.
If the box is being wired from the INSIDE of the
appliance:
• Remove the screw attaching the junction box/recep-
tacle to the outer shell, rotate the junction box/recep-
tacle inward to disengage it from the outer shell (see
Figure 10.3).
• Pull the electrical wires from outside the appliance
through this opening into the valve compartment.
• Feed the necessary length of wire through the
connector.
• Make all necessary wire connections to the junction
box/receptacle and reassemble the junction box/
receptacle to the outer shell.
E. Wall Switch Installation for Fan (Optional)
If the box is being wired to a wall mounted
switch for use with a fan (See Figure 10.4):
• The power supply for the appliance must
be brought into a switch box.
• The power can then be supplied from the
switch box to the appliance using a mini-
mum of 14-3 with ground wire.
• At the switch box connect the black (hot)
wire and red (switch leg) wire to the wall
switch as shown.
• At the appliance connect the black (hot),
white (neutral) and green (ground) wires
to the junction box as shown.
• Add a 1/4 inch insulated female connector
to the red (switch leg) wire, route it through
the knockout in the face of the junction box,
and connect to the top fan switch connector
(1/4 inch male) as shown.
Figure 10.3 Junction Box Detail
J U N C T IO N B O X
Figure 10.4 Fan Control Switch Wiring
Heat & Glo • SL-550 / 750 / 950TV-IPI-E • 2119-900 Rev. G • 9/08
GRN wire
inside box
M IN IM U M 1 4 -3 AW G
W IT H G R O U N D
R e d
B lac k
W h ite
G re e n
R e d
Romex
Connector
14/2WG
Cover Plate
outside firebox
Copper
ground attached
to GRN screw with
GRN wire
NOTE: Do NOT wire
110VAC to wall switch.
S W IT C H
B lac k
W h ite
G re e n
P O W E R
S U P P LY W IR E S
S W IT C H B O X
23