Electrical Information; Recommendation For Wire; Connecting To The Appliance; Intellifi Re Ignition System Wiring - Heat & Glo SL-750TV-IPI-E Owner's Manual

Fireplace
Hide thumbs Also See for SL-750TV-IPI-E:
Table of Contents

Advertisement

10
10

Electrical Information

A. Recommendation for Wire
This appliance requires 110-120 VAC be wired to the
junction box for use of optional accessories and proper
appliance of operation.
NOTE: This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local
codes, with National Electric Code ANSI/NFPA 70-latest
edition or the Canadian Electric Code, CSA C221.1.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
B. Connecting to the Appliance
WARNING
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
• Incorrect wiring will damage millivolt valves.
• Incorrect wiring will override IPI safety lockout
and may cause explosion.
• This appliance MUST be used with a wall switch or a
remote control.
• If using thermostat use one compatible with a millivolt
gas valve system.
• Follow parameters for locating thermostat (see individual
thermostat instructions) to ensure proper operation of
appliance.
• Use low resistance thermostat wire for wiring from igni-
tion system to the wall switch and thermostat.
• Keep wire lengths short as possible by removing any
excess wire length.
• Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
Heat & Glo • SL-550 / 750 / 950TV-IPI-E • 2119-900 Rev. G • 9/08
C. Intellifi re Ignition System Wiring
This appliance requires a 110 VAC supply to the appliance
junction box for operation. Wiring diagrams are shown in
Figures 10.1 and 10.2.
This appliance is equipped with an Intellifi re control valve
which operates on a 3 volt system.
This appliance is supplied with a battery pack and a 3 volt
AC transformer, which requires the installation of the sup-
plied junction box. It is highly recommended that the junc-
tion box be installed at this time to avoid reconstruction.
The battery pack requires two D cell batteries (not
included).
NOTE: Batteries cannot be placed in the battery pack
while using the 3 volt AC transformer. The transformer
must be unplugged if the battery pack is used or battery
life will be reduced.
CAUTION
Battery polarity must be correct or module damage will occur.
Optional Accessories Requirements
Wiring for optional accessories should be done now to
avoid reconstruction.
CAUTION
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
WARNING
Shock hazard.
• Replace damaged wire with type 105º C rated wire.
• Wire must have high temperature insulation.
CAUTION
Do not wire 110VAC directly to ignition module. Permanent
damage to module will occur. Connect ignition module to
3VAC transformer as instructed.
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl-550tv-ipi-eSl-950tv-ipi-e

Table of Contents