Heat & Glo SL-750TRSFHHIPI Owner's Manual
Heat & Glo SL-750TRSFHHIPI Owner's Manual

Heat & Glo SL-750TRSFHHIPI Owner's Manual

Hearth and home technologies gas fireplace installation & operating manual
Table of Contents

Advertisement

Quick Links

Model:
SL-750TRSFHHIPI
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH, in Canada.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08
Owner's Manual
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
Installation and Operation
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo SL-750TRSFHHIPI

  • Page 1 fi tter. See Table of Contents for location of additional Commonwealth of Massachusetts requirements. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 Owner’s Manual Installation and Operation • Leave this manual with party responsible for use and operation.
  • Page 2: Congratulations

    (Po. Col. d’eau) IN CANADA Mode l: 0-0000 FT . 0000-0000FT . (Modele): 00,000 00,000 00,000 00,000 Serial #XXXXX #XXXXX (Serie): Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 Model Number MADE IN US A Serial Number XXXXXXXX XXXXXXXX...
  • Page 3: Table Of Contents

    E. Junction Box Installation......52 F. Wall Switch Installation for Fan (Optional) ... . 52 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 4 D. Contact Information ......77 = Contains updated information. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 5: Limited Lifetime Warranty

    Page 1 of 2 Wood Pellet Electric Wood Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 Components Covered Venting All Parts and Material Except as covered by Conditions, Exclusion, and Limitations listed...
  • Page 6 If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide necessary parts or components, contact the nearest authorized HHT dealer or supplier. Page 2 of 2 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 4021-645A 09-01-08...
  • Page 7: Listing And Code Approvals

    Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 Models Maximum U.S. (0-2000 ft.) or Input Canada (2000-4500 ft.)
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 9: User Guide

    fi re or injury. DECORATIVE DOORS (NOT SHOWN) SECTION 2.E. FIXED GLASS ASSEMBLY (NOT SHOWN) SECTION 14.H. FAN KIT SECTION 2.C HEARTH CLEAR SPACE SECTION 2.D. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 MANTEL...
  • Page 10: Fan Kit (Optional)

    • Ensure that the glass is sealed and in the proper position and that the integral barrier is in place. WARNING! Risk of Fire or Asphyxiation! DO NOT op- erate fi replace with fi xed glass assembly removed. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 11: Lighting Instructions (Ipi)

    Bedroom or a Bedsitting Room. For assistance or additional informa- tion, consult a qualifi ed installer, ser- vice agency or the gas supplier. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 LIGHTING INSTRUCTIONS (IPI) 1. Turn off all electric power to the appliance.
  • Page 12: After Fireplace Is Lit

    In an Intellifi re ignition system it is normal to see the pilot fl ame, but it should turn off when ON/OFF is turned off. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 SOLUTIONS...
  • Page 13: Maintenance And Service

    If not using your fi replace for an extended period of time (summer months, vacations/trips, etc), to prevent unin- tended operation: • Remove batteries from remote controls. • Unplug 3 volt adapter plug on IPI models. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 14: Maintenance Tasks-Qualifi Ed Service Technician

    • Verify that there is not a short in fl ame sense circuit by checking continuity between pilot hood and fl ame sense rod. Replace pilot as necessary. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 15 (Either cobrahead or SIT) Figure 3.1 IPI Pilot Flame Patterns Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 16: Installer Guide

    FROM VENT PIPE IF ATTIC IS INSULATED (SECTION 8.D) FRAMING HEADED OFF IN CEILING JOISTS (SECTION 8.C) OPTIONAL WALL SWITCH MANTEL AND MANTEL LEG (SECTION 5.D) SURROUND HEARTH EXTENSION Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 HORIZONTAL TERMINATION CAP (SECTION 10.M)
  • Page 17: Design And Installation Considerations

    DO NOT use this appliance if any part has been under water. Call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 18: Framing And Clearances

    Actual installation may vary due to individual design preference. Min. Min. 64-3/8 See Section 45-1/2 D for Alcove 1635 1155 Installation Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 64-3/8 16-1/4 48-1/2 68-3/4 16-5/8 1635 1232 1737 7-1/2...
  • Page 19: Constructing The Appliance Chase

    Ceiling Opening Opening (Height) (Width) (Depth) (Depth) 38-1/4 16-1/4 16-1/4 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 MEASURE FROM TOP OF UNIT OPENING OR FROM TOP OF HOOD Combustible Combustible Behind Sides of Floor Flooring...
  • Page 20: Mantel And Wall Projections

    Note: Clearance from fi replace opening to perpendicular wall. Figure 5.6 Wall Projection (Acceptable on one side of opening.) 1/2 in. SHEETROCK Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 1/2 IN. TOP VIEW MINIMUM 2-7/8 IN.
  • Page 21: Termination Locations

    WOOD OR GAS TERMINATION * IF USING DECORATIVE CAP COVER(S), THIS DISTANCE MAY Figure 6.3 Leveled Termination Caps Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 DIRECT VENT GAS, WOOD OR FUEL OIL TERMINATION Minimum Dimensions Wood & Fuel Oil...
  • Page 22 Heat & Glo assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 (See Note 2) Measure vertical clearances from this surface.
  • Page 23: Vent Information And Diagrams

    • Vertical terminations are measured to bottom of termination cap. • Horizontal pipe installed level with no rise. Figure 7.2 DVP Pipe Effective Length Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 Vertical 8-1/2 in. Horizontal Effective Length...
  • Page 24: Use Of Flex Vent

    1 in. to combustibles. However, the vent at- CLEARANCE tachment point and the fi restop loca- tion are considered to be supports. Figure 7.3 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 25: Vent Diagrams

    • When using DVP-TB1 termination cap on top vented fi replaces, a three foot minimum vertical vent section is required before installing fi rst elbow. Figure 7.4 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 Maximum V Minimum SL-750TRSFHHIPI 90º...
  • Page 26 762 mm 3-1/2 ft. 1.1 m 4-1/2 ft. 1.4 m * See warning below INSTALLED HORIZONTALLY Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 H Maximum SL-750TRSFHHIPI NOT ALLOWED 1 ft. 305 mm 2 ft. 610 mm 4 ft.
  • Page 27 610 mm 4 ft. 1.2 m 6 ft. 1.8 m Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 Minimum Note: There MUST be a 25% reduction in total H when using fl ex vent except when using the simple up and out installation (see Figure 5.3).
  • Page 28 Top Vent Application Exhaust restrictor Rear Vent Application Exhaust restrictor Note: Be sure to re- install the inner heat shield after exhaust restrictor installation. Figure 7.8 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 INNER HEAT SHIELD...
  • Page 29 15 ft Maximum= 15 ft. (4.6 m) + H Maximum = 40 ft. (12.2 m) *No specifi c restrictions on this value EXCEPT V Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 305 mm 610 mm 762 mm 1.2 m...
  • Page 30 *No specifi c restrictions on this value EXCEPT V CANNOT exceed 40 ft. (12.2 m). INSTALLED HORIZONTALLY Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 Maximum 1-1/2 ft. 457 mm 1-1/2 ft. 457 mm 305 mm 610 mm 1.2 m...
  • Page 31 Four 90º Elbows Note: Use SLP Series components only. Figure 7.11 Min. 1-1/2 ft. 457 mm 4 ft. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 Max. Min. Max. 1.2 m 4 ft. 1.2 m 4 ft.
  • Page 32 5-1/2 ft. 1.7 m 2 ft. 610 mm 7-1/2 ft. 2.3 m 3 ft. 914 mm Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 90-DEGREE ELBOWS 1 ft. 305 mm 2-1/2 ft. 3 ft. 914 mm 6-1/2 ft.
  • Page 33 5-1/2 ft. 1.7 m 2 ft. 7-1/2 ft. 2.3 m 3 ft. Maximum = 7-1/2 ft. (2.3 m) Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 1 ft. 305 mm 2-1/2 ft. 305 mm 2 ft. 610 mm 5-1/2 ft.
  • Page 34 1 ft. 5-1/2 ft. 1.2 m 2 ft. 7-1/2 ft. 2.3 m 3 ft. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 Maximum 1/2 ft. 152 mm Back to Back Elbows 2-1/2 ft. 762 mm 1 ft.
  • Page 35: Vent Clearances And Framing

    * Shows center of vent framing hole for top or rear venting. The center of the hole is one (1) inch (25.4 mm) above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 10 in. 10 in. 10 in.
  • Page 36: Install The Ceiling Firestop

    BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP INSTALLED BELOW CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 ATTIC ABOVE PIPE 10 in. (254 mm) 9 in. (229 mm)
  • Page 37: Install Attic Insulation Shield

    BEND ALL TABS INWARD 90° TO MAINTAIN CLEARANCE AND PREVENT INSULATION FROM FALLING INSIDE Figure 8.5 Attic Insulation Shield Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 BEND 3 TABS OUTWARD TO FASTEN TO CEILING FIRESTOP-BEND REMAINING TABS...
  • Page 38: Appliance Preparation

    Figure 9.4 Remove the seal cap. Figure 9.5 Remove the insulation basket and white insula- tion from the center vent pipe. Figure 9.6 Remove the insulation from the outer vent pipe. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 39: Rear Vent

    Figure 9.12 Attach the fi rst vent section (it will snap into place). Slide the insulation gasket onto the vent section, up against the appliance and over the tabs. Use two self- tapping screws to secure gasket to outer wrap. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 40: Securing And Leveling The Appliance

    • Secure the appliance to the fl oor by inserting two screws through the pilot holes at the bottom of the appliance. NAILING TABS BOTH SIDES Figure 9.13 Proper Positioning and Securing of an Appliance Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 41: Installing Vent Pipe (Dvp And Slp Pipe)

    Figure 10.1 High Temperature Silicone Sealant Figure 10.2 Note: unintentional disconnection. Figure 10.4 Seams Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 Lances Lances Figure 10.3 Make sure that the seams are not aligned to prevent CORRECT...
  • Page 42: Assemble Vent Sections (Slp Pipe Only)

    • Only outer pipes are sealed, sealing the inner fl ue is not required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 Pilot hole Pilot hole...
  • Page 43: Secure The Vent Sections

    Figure 10.11. • Pull carefully to separate the pieces of pipe. Figure 10.10 Rotate Seams for Disassembly Figure 10.11 Align and Disassemble Vent Sections Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 44: Install Decorative Ceiling Components (Slp Only)

    GREATER IN SIZE THAN PATTERN OF SUPPORT BOX AS IT IS PROJECTED ONTO ROOF LINE Figure 10.12 Figure 10.13 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 LEVEL CATHEDRAL CEILING SUPPORT BOX 2 in. (51 mm) MIN. BELOW FINISHED CEILING...
  • Page 45: Install Metal Roof Flashing

    Figure 10.16 Assembling the Storm Collar Figure 10.16 Assembling the Storm Collar Figure 10.17 Assembling the Storm Collar Around the Pipe Figure 10.17 Assembling the Storm Collar Around the Pipe Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 CAULK...
  • Page 46: Install Rf4-8

    Figure 10.20 Apply Sealant Figure 10.21 Slide Flashing Down, Secure & Apply Sealant FLASHING OVER SHINGLES Figure 10.22 Installation Complete Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 APPLY SEALANT TOP & PARTIAL SIDES SILICONE SEALANT (TOP OF BOOT)
  • Page 47: Install Vertical Termination Cap

    • Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section. Important Notice: Heat shields may not be fi eld constructed. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 48: Install Horizontal Termination Cap (Dvp And Slp Pipe)

    DVP-TRAP2 can adjust 4 in. (5-3/8 to 9-3/8) DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8) DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2) Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 HEAT SHIELD OR EXTENDED HEAT SHIELD...
  • Page 49: Gas Information

    • In the USA: Reduce burner orifi ce 4% for each 1000 feet above 2000 feet. • In CANADA: Reduce burner orifi ce 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 50: Electrical Information

    Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 51: Electrical Service And Repair

    WARNING! Risk of Shock! Replace damaged wire with type 105° C rated wire. Wire must have high temperature insulation. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 NOTE: 1. Ignition module, valve, pilot, and wall switch operate on 3 volts. 120 VAC is required at junction box unless equipped with battery back-up.
  • Page 52: Junction Box Installation

    (1/4 in. male) as shown. Figure 12.3 Junction Box Detail Junction Box Figure 12.4 Junction Box Wired to Wall Switch or BC10 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 Romex Connector Cover Plate outside firebox...
  • Page 53: Finishing

    The top slot is indicated in Figure 13.5 Take care not to bend or break off the tabs. Figure 13.4 Figure 13.5 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 TOP SLOT...
  • Page 54 Carefully grab splatter guard on or near the vertical center on the left and right sides. Pull outward gently, but fi rmly, taking care not to tear or remove the inserted tabs. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 55: Mantel And Wall Projections

    Figure 13.14 Wall Projection (Acceptable on one side of opening) 1/2 IN. MINIMUM Figure 13.15 Non-Combustible Zone Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 3 IN. TOP VIEW MINIMUM 5-3/8 IN. MINIMUM UNLIMITED 1/2 in.
  • Page 56: Facing Material

    Note: There are 3 metal tabs holding the non-combustible board in place for shipping. These tabs are to be cut off or bent back before fi nishing around the appliance front. 0 IN. 1 IN. 0 IN. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 57: Doors

    MATERIAL 1 in. MAX (TOP EDGE) Figure 13.20 Operable Hinge Door (Halston) Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 DOOR (Includes 1/8 in. opening each side of door) Finishing material between 1 and 4 inches thick.
  • Page 58: Elevated Hearth Systems

    CAMM36PGH ESSEX36PG ESSEX36PGH ESSEXM36PG ESSEXM36PGH LUNA-36-GY MON36PG MON36PGH MONM36PG MONM36PGH Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 ELEVATED APPLIANCE MARBLE LEG CUT DIMENSION LENGTH See Note 1 See Note 2 32-7/8 in. 9-1/4 in. 32-7/8 in.
  • Page 59: Appliance Setup

    Use this material to give the appliance a realistic ash bed. JUNCTION BOX • Save the remaining ember materials for use during appliance servicing. The embers provided should be enough for 3 to 5 applications. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 60: Install Refractory

    Bend left and right refractory retainer tabs to keep side pieces from tipping (see Figure 14.6). Figure 14.6 Step 4. Install logs according to the install manual. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 REFRACTORY REFRACTORY RETAINER TAB RETAINER TAB...
  • Page 61: Install The Log Assembly

    The pilot should be centered within the large notch on log #2. Log Set Assembly: LOGS-SL750TRS- D Models: SL-750TRS-IPI-D, SL-750TRS-IPI-E LOG NOTCHES Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 SL-750TRSFHHIPI 2066-935...
  • Page 62 Log #4. See Figure 14.8. LOG/BURNER DETAIL CONTACT AREA Figure 1. Figure 14.7 Figure 14.8 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 LOG TOUCHES REFRACTORY PANEL NOTCH MATE WITH GROOVES HERE...
  • Page 63: Fixed Glass Assembly

    fl ame appearance. This should be adjusted by a qualifi ed installer at the time of installation. SL-750TRSFHHIPI SL-750TRSFHHIPI (LP) Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 3/8 in. Fixed...
  • Page 64: Troubleshooting

    .17 in. or 1/8 in. (3 mm). Verify module is securely grounded to metal chassis of appliance. Verify battery voltage is at least 2.7 volts. Replace batteries if volt- age is below 2.7. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 Corrective Action...
  • Page 65 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fi ne. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 Corrective Action...
  • Page 66: Reference Materials

    Figure 16.1 Appliance Dimensions Ø Inches Millimeters Location 1041 36-1/8 32-1/16 21-1/2 34-5/8 3-9/16 6-7/8 26-7/8 37-7/8 1015 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 ELECTRICAL ACCESS Inches Millimeters 8-13/16 16-5/16 30-3/4 15-3/8 15-7/8 6-5/8 2-3/16 33-9/16 Ø...
  • Page 67: Vent Components Diagrams

    DVP-FS (Ceiling Firestop) 1- 1/2 in. (38 mm) 14 in. (356 mm) 12 in. (305 mm) Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 10-1/2 in. (267 mm) 4-7/8 in. ( 276 mm) 10-7/8 in. (276 mm) DVP45 (45º...
  • Page 68 DVP-TRAPK1 DVP-HPC1 Figure 16.3 DVP vent components 8 in. Heat (203 mm) Shield Effective Length Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 Minimum Maximum Term Cap Effective Length Effective Length 3-1/8 in. 4-5/8 in. Trap1 79 mm 117 mm 5-3/8 in.
  • Page 69 7-1/8 in. (181 mm) 5-3/4 in. (146 mm) 13-7/8 in. (352 mm) 14 in. (356 mm) Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 31 in. (787 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak 11-7/8 in.
  • Page 70 (133 mm) VerticalTermination Cap (Highwind) 14 in. (356 mm) 7-1/8 in. (181 mm) 8-3/4 in. (222 mm) Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 3-7/8 in. (98 mm) 10-1/2 in. (267 mm) DVP-TV VerticalTermination Cap 12 in.
  • Page 71 SLP-HRC-SS SLP-HRC-ZC-SS HORIZONTAL TERMINATION CAP DVP-TB1 SL-2DVP SLP90 ASSEMBLY DVP-TB1 HORIZONTAL TERMINATION CAP Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 5-1/2 in. 8-3/8 in. 140 mm 213 mm 3° 87° 10-1/2 in. 267 mm 10-7/8 in.
  • Page 72 SLP-FLEX-2 SLP-FLEX-3 SLP-FLEX-5 1524 SLP-FLEX-10 3048 RF4-8 Roof Flashing Ceiling Firestop Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 6-1/2 in. 165 mm 6-1/2 in. 165 mm 9-1/4 in. 235 mm 6-5/8 in. 168 mm 9-7/8 in.
  • Page 73 (For use with IPI and DSI appliances only.) Termination Cap Termination Cap SLP-WT-BK Wall Thimble-Black SL-2DVP Adapter DVP-FBHT DVP-FBHT SL-2DVP SLP90 SLP-FLEX-TRAP Horizontal Termination Kit Figure 16.9 SLP Series Vent Components Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 74: Service Parts

    SL-750TRSFHHIPI C. Service Parts Beginning Manufacturing Date: Oct. 2007 Service Parts Diagram Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08...
  • Page 75 Pilot Orifi ce NG Pilot Orifi ce LP Regulator NG Regulator LP Additional service part numbers appear on following page. CCOMMENTS Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 SL-750TRSFHHIPI Stocked at Depot PART NUMBER LOGS-750TRS-D SRV2066-704...
  • Page 76 Battery Pack Flexible Gas Connector Orifi ce NG (#37) Orifi ce LP (#52) High Temp Limit Switch Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 SL-750TRSFHHIPI Beginning Manufacturing Date: Oct. 2007 Ending Manufacturing Date: ______ COMMENTS PART NUMBER...
  • Page 77: Contact Information

    • Read, understand and follow these instructions for safe installation and operation. Printed in U.S.A. - Copyright 2008 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08 • Leave this manual with party responsible for use and operation.

Table of Contents