Drain Pan; Freeze Protection; Furnace Suspension; Lternate Lectrical And As Ine Onnections - Goodman GMV95 Installation Instructions Manual

Two-stage gas-fired warm air furnace
Table of Contents

Advertisement

AIR
DISCHARGE
Side
Return
Duct
Connection
AIR
DISCHARGE
UPFLOW HORIZONTAL
LEFT AIR DISCHARGE
Bottom
Return
Duct
Connection
UPFLOW HORIZONTAL
RIGHT AIR DISCHARGE
Recommended Installation Positions
NOTE: Alternate "vertical" piping connections can not be used when
an upflow furnace is installed with supply air discharging to the
right, or when a counterflow furnace is installed with supply air
discharging to the left. In either case, use the standard flue and
combustion air piping connections.
A
E
LTERNATE
LECTRICAL AND
This furnace has provisions allowing for electrical and gas line
connections through either side panel. In horizontal applications
the connections can be made either through the "top" or "bottom" of
the furnace.
D
P
RAIN
AN
A drain pan must be provided if the furnace is installed above a
conditioned area. The drain pan must cover the entire area under
the furnace (and air conditioning coil if applicable).
F
P
REEZE
ROTECTION
Refer to Section VII, Horizontal Applications and Conditions - Drain
Trap and Lines.
F
S
URNACE
USPENSION
If the furnace is installed in a crawl space it must be suspended
from the floor joist or supported by a concrete pad. Never install the
furnace on the ground or allow it to be exposed to water. Refer to
Section IV, Location Requirements and Considerations - Furnace
Suspension for further details.
VIII. PROPANE GAS /HIGH ALTITUDE INSTALLATIONS
P
OSSIBLE PROPERTY DAMAGE
OCCUR IF THE CORRECT CONVERSION KITS ARE NOT INSTALLED
APPROPRIATE KITS MUST BE APPLIED TO ENSURE SAFE AND PROPER
. A
FURNACE OPERATION
LL CONVERSIONS MUST BE PERFORMED BY
A QUALIFIED INSTALLER OR SERVICE AGENCY
This furnace is shipped from the factory configured for natural gas
at standard altitude. Propane gas installations require an orifice
change to compensate for the energy content difference between
natural and propane gas.
High altitude installations may require both a pressure switch and
an orifice change. These changes are necessary to compensate
ALTERNATE FLUE AND
COMBUSTION AIR PIPE
LOCATIONS
Side
Return
Duct
Connection
Bottom
Return
Duct
Connection
UPFLOW
UPRIGHT
ALTERNATE FLUE AND
COMBUSTION AIR PIPE
LOCATIONS
Bottom
Return
Duct
Connection
AIR
DISCHARGE
G
L
C
AS
INE
ONNECTIONS
WARNING
,
PERSONAL INJURY OR DEATH MAY
.
for the natural reduction in the density of both the gas fuel and the
combustion air at higher altitude.
For installations above 7000 feet, please refer to your distributor
for required kit(s).
Gas
Altitude
Natural
None
0-7000
Propane
LPM-03*
NOTE: In Canada, gas furnaces are only certified to 4500 feet.
Contact the distributor for a tabular listing of appropriate
manufacturer's kits for propane gas and/or high altitude installa-
tions. The indicated kits must be used to insure safe and proper
furnace operation. All conversions must be performed by a quali-
fied installer, or service agency.
IX. VENT/FLUE PIPE & COMBUSTION AIR PIPE
G

ENERAL

F
AILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN BODILY
. C
INJURY OR DEATH
INSTRUCTIONS GIVEN IN THIS SECTION
U
PON COMPLETION OF THE FURNACE INSTALLATION
INSPECT THE ENTIRE FLUE SYSTEM BOTH INSIDE AND OUTSIDE OF
THE FURNACE TO ASSURE IT IS PROPERLY SEALED
FLUE SYSTEM CAN RESULT IN SERIOUS PERSONAL INJURY OR DEATH
DUE TO EXPOSURE TO FLUE PRODUCTS
.
MONOXIDE
A condensing gas furnace achieves its high level of efficiency by
extracting almost all of the heat from the products of combustion
and cooling them to the point where condensation takes place.
Because of the relatively low flue gas temperature and water con-
densation requirements, PVC pipe is used as venting material.
This furnace must not be connected to Type B, BW, or L vent or vent
connector, and must not be vented into any portion of a factory built
or masonry chimney except when used as a pathway for PVC as
described later in this section. Never common vent this appliance
with another appliance or use a vent which is used by a solid fuel
appliance. Do not use commercially available "no hub connec-
tors" other than those shipped with this product.
It is the responsibility of the installer to follow the manufacturers'
recommendations and to verify that all vent/flue piping and connec-
tors are compatible with furnace flue products. Additionally, it is the
responsibility of the installer to ensure that all piping and connec-
tions possess adequate structural integrity and support to prevent
flue pipe separation, shifting, or sagging during furnace operation.
D
C
UAL
ERTIFICATION
This furnace is dual certified and may be installed as a non-direct
. T
HE
vent (single pipe) or direct vent (dual pipe) appliance. A non-direct
vent installation requires only a vent/flue pipe, while a direct vent
installation requires both a vent/flue pipe and a combustion air
intake pipe. Refer to the appropriate section for details concerning
piping size, length, number of elbows, furnace connections, and
terminations.
12
Manifold Pressure
Kit
Orifice
High Stage Low Stage
#43
3.5" w.c.
1.9" w.c.
#55
10.0" w.c.
6.0" w.c.
WARNING
AREFULLY READ AND FOLLOW ALL
.
WARNING
,
INCLUDING CARBON
: N
-D
/D
V
ON
IRECT
IRECT
Pressure
Switch Change
None
None
,
CAREFULLY
. L
EAKS IN THE
ENT