Alternate Electrical And Gas Line Connections; Drain Pan; Freeze Protection; Furnace Suspension - Goodman GCH95 Installation Instructions Manual

Gas-fired warm air furnace
Hide thumbs Also See for GCH95:
Table of Contents

Advertisement

AIR
DISCHARGE
ALTERNATE FLUE PIPE
LOCATION
Side
Side
Return
Return
Duct
Duct
Connection
Connection
Bottom
Return
Duct
Connection
UPFLOW
UPRIGHT
ALTERNATE FLUE
PIPE LOCATION
Bottom
Return
AIR
Duct
DISCHARGE
Connection
UPFLOW HORIZONTAL
LEFT AIR DISCHARGE
Bottom
Return
AIR
Duct
DISCHARGE
Connection
UPFLOW HORIZONTAL
RIGHT AIR DISCHARGE
Recommended Installation Positions
NOTE: Alternate "vertical" piping connections can not be used when
an upflow furnace is installed with supply air discharging to the
right, or when a counterflow furnace is installed with supply air
discharging to the left. In either case, use the standard flue and
combustion air piping connections.
A
E
LTERNATE
LECTRICAL AND
This furnace has provisions allowing for electrical and gas line
connections through either side panel. In horizontal applications
the connections can be made either through the "top" or "bottom" of
the furnace.
D
P
RAIN
AN
A drain pan must be provided if the furnace is installed above a
conditioned area. The drain pan must cover the entire area under
the furnace (and air conditioning coil if applicable).
F
P
REEZE
ROTECTION
Refer to Section VII, Horizontal Applications and Conditions - Drain
Trap and Lines.
F
S
URNACE
USPENSION
If the furnace is installed in a crawl space it must be suspended
from the floor joist or supported by a concrete pad. Never install the
ALTERNATE FLUE AND
Bottom
COMBUSTION AIR PIPE
Return
LOCATIONS
Duct
Connection
AIR
DISCHARGE
COUNTERFLOW
UPRIGHT
ALTERNATE FLUE AND
COMBUSTION AIR PIPE
LOCATIONS
Bottom
Return
Duct
Connection
COUNTERFLOW HORIZONTAL
RIGHT AIR DISCHARGE
AIR
Connection
DISCHARGE
COUNTERFLOW HORIZONTAL
LEFT AIR DISCHARGE
G
L
C
AS
INE
ONNECTIONS
furnace on the ground or allow it to be exposed to water. Refer to
Section IV, Location Requirements and Considerations - Furnace
Suspension for further details.
VIII. PROPANE GAS /HIGH ALTITUDE INSTALLATIONS
P
OSSIBLE PROPERTY DAMAGE
OCCUR IF THE CORRECT CONVERSION KITS ARE NOT INSTALLED
APPROPRIATE KITS MUST BE APPLIED TO ENSURE SAFE AND PROPER
FURNACE OPERATION
A QUALIFIED INSTALLER OR SERVICE AGENCY
This furnace is shipped from the factory configured for natural gas
at standard altitude. Propane gas installations require an orifice
change to compensate for the energy content difference between
natural and propane gas.
High altitude installations may require both a pressure switch and
an orifice change. These changes are necessary to compensate
for the natural reduction in the density of both the gas fuel and the
combustion air at higher altitude.
For installations above 7000 feet, please refer to your distributor
for required kit(s).
Altitude
Natural
0-7000
AIR
DISCHARGE
Propane
NOTE: In Canada, gas furnaces are certified to 4500 feet.
Contact the distributor for a tabular listing of appropriate
manufacturer's kits for propane gas and/or high altitude installa-
Bottom
tions. The indicated kits must be used to insure safe and proper
Return
Duct
furnace operation. All conversions must be performed by a quali-
fied installer, or service agency.
IX. VENT/FLUE PIPE & COMBUSTION AIR PIPE
G
ENERAL
F
AILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN BODILY
INJURY OR DEATH
INSTRUCTIONS GIVEN IN THIS SECTION
U
PON COMPLETION OF THE FURNACE INSTALLATION
INSPECT THE ENTIRE FLUE SYSTEM BOTH INSIDE AND OUTSIDE OF
THE FURNACE TO ASSURE IT IS PROPERLY SEALED
FLUE SYSTEM CAN RESULT IN SERIOUS PERSONAL INJURY OR DEATH
DUE TO EXPOSURE TO FLUE PRODUCTS
.
MONOXIDE
A condensing gas furnace achieves its high level of efficiency by
extracting almost all of the heat from the products of combustion
and cooling them to the point where condensation takes place.
Because of the relatively low flue gas temperature and water con-
densation requirements, PVC pipe is used as venting material.
This furnace must not be connected to Type B, BW, or L vent or vent
connector, and must not be vented into any portion of a factory built
or masonry chimney except when used as a pathway for PVC as
12
WARNING
,
PERSONAL INJURY OR DEATH MAY
. A
LL CONVERSIONS MUST BE PERFORMED BY
.
HIGH ALTITUDE GAS ORIFICE CHART
Gas
Kit
Orifice
None
#43
LPM-05
#55
WARNING
. C
AREFULLY READ AND FOLLOW ALL
.
WARNING
,
INCLUDING CARBON
. T
HE
Manifold
Pressure
Pressure
Switch
3.5" w.c.
None
10.0" w.c.
,
CAREFULLY
. L
EAKS IN THE