Alternate Electrical And Gas Line; Propane Gas/High Altitude Installations; Drain Pan; Freeze Protection - Goodman *CVC96 Installation Instructions Manual

Goodman *cvc96; *mvc96 two-stage gas furnace
Table of Contents

Advertisement

When using the horizontal alternate vent configuration, you must use the RF000142 vent drain kit. See following illustration.
Alternate Vent/Flue Location
A
E
LTERNATE
LECTRICAL AND
This furnace has provisions allowing for electrical and gas line
connections through either side panel. In horizontal applications the connections can be made either through the "top" or "bottom"
of the furnace.
D
P
RAIN
AN
A drain pan must be provided if the furnace is installed above a conditioned area. The drain pan must cover the entire area under the
furnace (and air conditioning coil if applicable).
F
P
REEZE
ROTECTION
Refer to Horizontal Applications and Conditions - Drain Trap and Lines.
P
G
/H
A
ROPANE
AS
IGH
This furnace is shipped from the factory configured for natural gas
at standard altitude. Propane gas installations require an orifice
and orifice change to compensate for the energy content differ-
ence between natural and propane gas.
High altitude installations may require both a pressure switch and
an orifice/spring change. These changes are necessary to com-
pensate for the natural reduction in the density of both the gas fuel
and the combustion air at higher altitude.
For installations above 7000 feet, please refer to the furnace Speci-
fication Sheets for required kit(s).
Contact the distributor for a tabular listing of appropriate
manufacturer's kits for propane gas and/or high altitude installa-
tions. The indicated kits must be used to insure safe and proper
furnace operation. All conversions must be performed by a qualified
installer, or service agency.
Figure 3A
G
L
C
AS
INE
ONNECTIONS
I
L TITUDE
NSTALLATIONS
Recommended Installation Positions
P
OSSIBLE PROPERTY DAMAGE
OCCUR IF THE CORRECT CONVERSION KITS ARE NOT INSTALLED
APPROPRIATE KITS MUST BE APPLIED TO ENSURE SAFE AND PROPER
. A
FURNACE OPERATION
QUALIFIED INSTALLER OR SERVICE AGENCY
Gas
A ltitude
Kit
Natural
No ne
0-7000
LP M -08*
P ro pane
1
1
LP M -08* suppo rts bo th Honeywell and White-Rodgers 2-stage valves
N O T E : In Canada, gas furnaces are only certified to 4500 feet.
11
Figure 3B
Figure 3C
WARNING
,
PERSONAL INJURY OR DEATH MAY
LL CONVERSIONS MUST BE PERFORMED BY A
.
M anifo ld P ressure
Orifice
High
Lo w
Stage
Stage
# 45
3.5" w.c.
1 .9" w.c.
1 .25mm
10.0" w.c.
6.0" w.c.
. T
HE
P ressure
Switch
Change
None
None