4.9.6 Ignition Transformer
Part
Function
Failure Event
Effects
Error Code
Diagnostic
Color/Number of wires
Input Voltage
120 V, 60 Hz
To ignite gas by repeatedly discharging a high voltage spark to the main burner until gas ignites.
1. Unable to ignite during the ignition process.
2. Produces multiple unsuccessful attempts to ignite.
1. The unit cannot ignite during the ignition process and "E003" or "E004" error codes will display.
2. Durability of the igniter wears down.
E003, E004
1. Visual inspection: Connection and/or breakage of wires.
2. Voltage check: Check range of voltage shown below.
Blue
On : AC 97 ~ 138 V
Off : 0 V
Output Voltage
Output Current
20 KV ±
10mA ± 2mA
Check Point