Check method
Fault
Possible Causes
temperature sensor
Defective sensor
Temperature sensor
Defective PCB
Possible Issues
Defective
Check if the temperature sensor is open and if the connector is connected properly.
connector
Check the resistance of the temperature sensor. (Defective if it is 30kΩ or higher)
If the issues continue despite checking the items above, replace the PCB.
<Heat exchanger output temperature sensor / connector>
Check if the secondary water temperature sensor is open Error type : MΩ Open>
Check method
Replace the temperature sensor if the resistance value is abnormal.
Check the temperature displayed on the front panel.