Ignition Transformer - Navien NCB500-2S/37K Service Manual

Condensing combi boiler
Table of Contents

Advertisement

4.7.6 Ignition Transformer

Item
Function
Fault
Symptoms
Error codes
Diagnostics
Testing/inspection
information
Input Voltage
230 V, 50 Hz
Provides voltage for the igniter for gas ignition purposes.
1. The igniter is unable to ignite the gas.
2. Results in multiple unsuccessful ignition attempts to.
1. The boiler does not ignite and error code E003 or E004 is displayed.
2. Durability of the transformer wears down.
E003, E004
1. Visual inspection: Check wire connections are secure and inspect for wire damage.
2. Voltage test: Test the voltage meets the specifications shown below.
BROWN - BLUE
On: AC 230 V
Off: 0 V
Output Voltage
Output Current
±20 kV
10 mA, ±2 mA
Description
System Details
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ncb500-2s+/41k

Table of Contents