6. Re-open the manual gas valve and check for leaks.
7. Open multiple fixtures that have high flow rates, such as
bathtub and shower faucets, to allow the boiler to operate
up to its maximum firing rate.

4.2.1 Gas Pipe Sizing Tables (Referenced from 2012 National Fuel Gas Code)

These tables are for reference only. Please consult the gas pipe manufacturer for actual pipe capacities.
Maximum Natural Gas Delivery Capacity
in Cubic Feet (ft
3
) per Hour (0.60 Specific Gravity; 0.5" WC Pressure Drop). Contact your gas supplier for BTU/ft
BTU/ft3 for simplified calculations. This table is recommended for supply pressures less than 6" WC.
Length (including fittings)
Pipe
10'
20'
Size
(3m)
(6m)
3/4"
360
247
1"
678
466
1 1/4"
1,390
957
1 1/2"
2,090
1,430
2"
4,020
2,760
2 1/2"
6,400
4,400
3"
11,300
7,780
4"
23,100
15,900
24
NCB Service Manual
30'
40'
50'
(9m)
(12m)
(15m)
199
170
151
374
320
284
768
657
583
1,150
985
873
2,220
1,900
1,680
3,530
3,020
2,680
6,250
5,350
4,740
12,700
10,900
9,660
8. When the boiler reaches its maximum firing rate, check the
inlet gas pressure reading on the manometer. The gas
pressure must fall within the proper operating range
indicated in the previous page and also in the
specifications on page 17.
60'
70'
80'
(18m)
(21m)
(24m)
137
126
117
257
237
220
528
486
452
791
728
677
1,520
1,400
1,300
2,430
2,230
2,080
4,290
3,950
3,670
8,760
8,050
7,490
3
ratings. Use 1,000
90'
100'
125'
(27m)
(30m)
(38m)
110
104
92
207
195
173
424
400
355
635
600
532
1,220
1,160
1,020
1,950
1,840
1,630
3,450
3,260
2,890
7,030
6,640
5,890
Version 1.0