Severity
(appears as
part of severity
field)
Critical
Configuration Mismatch
Critical
Operational Code Missing
Critical
Configuration Data Missing
Critical
Power Degrade
Critical
IVR Configuration Missing
Critical
RADIUS Configuration Missing
Critical
RADIUS Server Not Responding
Critical
IVR Configuration Missing
Major
Major Software Error
P/N 480-0005-00-15
Alarm Description
(text appears in desc field)
Chapter 7: System Alarms
Definition
A mismatch has occurred for the card in the slot and the
actual configuration. For example, this alarm would
occur if you insert a DSP card in a slot that has an earlier
configuration for a T1 card.
Normal application code for T1/E1, System Controller,
CPU, or DSP card is damaged.
Configuration via CLI is missing. Check the configura-
tion data and add the necessary information.
One power supply is not working correctly.
Appears if an attempt to make an IVR call has been
made when a valid IP address is not configured.
If an IVR call has been passed through accidently, with-
out a real intention to use IVR for subsequent calls,
while both of the servers were disabled. In order to clear
the alarm, a user will have to change one of the IP
addresses to some value, and then disable it again.
Appears when a RADIUS request is made and one or
more required configuration parameters are missing.
This alarm is cleared when the required RADIUS
parameters are configured via CLI.
Appears when none of the configured RADIUS servers
respond.
This alarm is cleared when any of the RADIUS servers
responds or the RADIUS server is disabled via CLI.
Appears if an attempt to make an IVR call has been
made while neither of the two IVR Prompt Server IP
addresses are set in the database; an IVR enabled trunk
group receives a call for which the IVR Prompt Server
IP is not configured.
If an IVR call has been passed through accidentally,
without a real intention to use IVR for subsequent calls,
while both of the servers were disabled. In order to clear
the alarm, a user will have to change one of the IP
addresses to some value, and then disable it again.
A software error has occurred that affects system signal-
ing, interfaces, or other major operation.