2.7.3 Alarm Connections

This section explains the connections to the ALARM port.
Figure 49 ALARM Connector Pin Layout
A closed circuit on the ALARM input pins indicates an alarm.
• Pins 1 and 9 are alarm input one.
• Pins 2 and 10 are alarm input two.
• Pins 3 and 11 are alarm input three.
The IES signals an alarm when it detects an alarm on the ALARM input pins, the
IES is overheated, the voltage readings are outside the tolerance levels, a fan
fails, or another alarm occurs.
To signal a minor alarm, the MSC opens the circuit for pins 4 and 12 and closes the
circuit for pins 5 and 12.
To signal a major alarm, the MSC opens the circuit for pins 13 and 6 and closes
the circuit for pins 14 and 6.
To signal a critical alarm, the MSC opens the circuit for pins 7 and 15 and closes
the circuit for pins 8 and 15.

2.8 Power Connections

Use the following procedures to connect the IES to a power source after you have
installed the main chassis in a rack.
Refer to
sure you are using an appropriate power source.
Observe the following before you start:
• Refer to
Chapter 5 on page 75
connections.
IES-5106M / IES-5112M / IES-6000M User's Guide
Chapter 5 on page 75
for the gauge of wire to use for the IES power
Chapter 2 Hardware Installation and Connections
for power requirements and make