Ras-18Ukpx3-T2 / Ras-18Uax3-T2 - Toshiba RAS-24UKHP-E3 Service Manual

Toshiba split wall type air conditioner service manual
Table of Contents

Advertisement

5-8. RAS-18UKPX3-T2 / RAS-18UAX3-T2

0.39 m
(Connecting pipe)
∅15.88
O.D.:15.88 mm
P
Packed valve
Accumulator
PH210T2-4L7
Compressor
50 Hz
Standard
Cooling
High temperature
Low temperature
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Cross flow fan
(∅15.88)
Condenser
Propeller fan
Outdoor unit
Standard
pressure P
(MPaG)
0.4
0.6
0.3
T
Indoor unit
Evaporator
Surface temp. of heat
exchanger interchanging
pipe T (°C)
10.0
12.0
2.0
– 27 –
FILE NO. SVM-04008
0.49 m
(Connecting pipe)
∅6.35
O.D.:6.35 mm
Packed valve
(∅6.35)
Capillary tube
∅2.0x800 s
Refrigerant
R22 1.47 kg
Mark (
) means check points of Gas Leak
Ambient temp.
conditions DB/WB
Fan speed
(°C)
(indoor)
Indoor
High
27/19
High
32/23
Low
21/15
Outdoor
35/24
43/26
21/15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents