Specification Of Electrical Parts; Indoor Unit (Ras-24Ukhp-E3, Ras-18Ukhp-E3); Outdoor Unit (Ras-24Uah-E3) - Toshiba RAS-24UKHP-E3 Service Manual

Toshiba split wall type air conditioner service manual
Table of Contents

Advertisement

4. SPECIFICATION OF ELECTRICAL PARTS

4-1. Indoor Unit (RAS-24UKHP-E3, RAS-18UKHP-E3)

No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
DC-DC transformer (T01)
4
Microcontroller
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Diode (DB01)
8
Capacitor (C02)
9
Fuse (F01)
10
Power supply IC (IC01)
11
Varistor (R21, R22)
12
Resistor (R01)
13
Louver motor

4-2. Outdoor Unit (RAS-24UAH-E3)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Solenoid coil
5
(for 4-way valve)
6
Thermo sensor
7
Magnetic contactor
8
Transformer
9
Microcontroller
10
Varistor (R73, R74, R86)
11
Fuse (F01)
Type
ICF-340-30-2
———
SWT-58A
TMP87CM40AN
———
SS11V-R07190
D3SBA60
KMH450VNSN120M25C
TSCR
MA8920
15G561K
RF-5TK4R7
MP35EA12
Type
Output (Rated) 2200 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
PH310X3-4MM
Winding resistance (Ω)
(at 20°C)
Output (Rated) 65 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
KFG6-71SB5P-T1 Winding resistance (Ω)
(at 20°C)
451355KQ
AC 450 V, 3.5µF
DS441606CPNE
AC 440 V, 60µF
VHV (STF)
AC 220 – 240 V
TE / TD
10 kΩ at 25°C / 50 kΩ at 25°C
CLK-35J
220 − 240 V, 50 Hz
TT-05
220 – 240 V
TMP47C840N
15G471K
470 V
MT3
T6.3 A, 250 V
– 16 –
FILE NO. SVM-04008
Specifications
DC 340 V, 30 W
10 kΩ at 25°C
DC 390 V, Secondary DC 15 V, 12 V, 7 V
10 kΩ at 25°C
19 mH, AC 0.7 A
4 A, 600 V
120µF, 450 V
T6.3 A, 250 V
5 A, 900 V
560 V
4.7 Ω, 5 W
Output (Rated) 2 W, 10 poles, 1 phase,
DC 12 V
Specifications
C-R
0.8
Red-Black
64.4
C-S
2.16
White-Black
127.4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents