5-4. RAS-24UKPX3 / RAS-24UAX3
RAS-24UKPX3-T / RAS-24UAX3-T
Cooling
0.39 m
(Connecting pipe)
∅15.88
P
O.D.:15.88 mm
Packed valve
(∅15.88)
Gas container connection (Reinstall etc.)
Cooling
Cooling Compressor
Cooling
50 Hz
Standard
Cooling
High temperature
Low temperature
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Indoor unit
Evaporator
Cross flow fan
2JS386D5BB02
Condenser
Propeller fan
Outdoor unit
Standard
Surface temp. of heat
pressure P
exchanger interchanging
(MPaG)
pipe T (°C)
0.4
0.7
0.3
– 23 –
FILE NO. SVM-04008
T
Packed valve
(∅6.35)
Capillary tube
∅ 2.0x650
Dryer
Refrigerant
R22 1.80 kg
Mark (
) means check points of Gas Leak
Fan speed
(indoor)
11.0
High
12.0
High
1.0
Low
0.49 m
(Connecting pipe)
∅6.35
O.D.:6.35 mm
l
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
27/19
35/24
32/23
43/26*
21/15
21/15