Ras-18Ukpx3 / Ras-18Uax3 - Toshiba RAS-24UKHP-E3 Service Manual

Toshiba split wall type air conditioner service manual
Table of Contents

Advertisement

5-6. RAS-18UKPX3 / RAS-18UAX3

0.39 m
(Connecting pipe)
∅12.7
O.D.:12.7 mm
P
Packed valve
(∅12.7)
Compressor
2JS350D5DA02
50 Hz
Standard
Cooling
High temperature
Low temperature
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Indoor unit
Evaporator
Cross flow fan
Condenser
Propeller fan
Outdoor unit
Standard
Surface temp. of heat
exchanger interchanging
pressure P
(MPaG)
pipe T (°C)
0.4
0.5
0.3
– 25 –
FILE NO. SVM-04008
T
Packed valve
(∅6.35)
Capillary tube
∅2.0x700 s
Refrigerant
R22 1.05 kg
Mark (
) means check points of Gas Leak
Fan speed
(indoor)
11.0
High
13.0
High
2.0
Low
0.49 m
(Connecting pipe)
∅6.35
O.D.:6.35 mm
Dryer
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
27/19
35/24
32/23
43/26
21/15
21/15